TROUBLESHOOTING
Volts
~115V
Running AMPS
6.0
Minimum Operating
55°F (12.5°C) Allow to acclimate
Temperature
to room temperature if stored
below 55°F (12.5°C)
Frequency
60 Hz
Standard Hose Length 7 ft. (2.13 m)
Dimensions
25 3/8 in. (64 cm) H x 10 1/16 in.
(26 cm) W x 17 1/8 in. (43 cm) L
Air Line Pressure
35 psi (2.4 Bar)
Weight – Empty
43 lbs (20 kg)
Weight – Full
59 lbs (27 kg)
Shipping Weight
52 lbs (24 kg)
Flow Rate
110–130 mL/min
Potential Issue
Damage to nozzle
assembly
Damage to peristaltic
pump tubing
Dirty exterior sprayer
surfaces
Potential Issue
No power
System is not
switched on
Compressor shuts off
suddenly or won’t run
while depressing the
sprayer trigger
Compressor has
overheated
Unit stalls upon
initial spray
Corrective Action
Inspect for damage and faulty
parts. If present, contact
Service Tech Team.
Replace pump tubing. Visit
www.servicetechteam.com
to request replacement parts.
Clean exterior surfaces with
70% isopropyl alcohol.
Corrective Action
Verify the unit is plugged in and
on a known working power outlet
Depress power switch to illumi-
nate, or toggle power switch to
the ON position.
This is a sign that the unit’s circuit
breaker has tripped or the com-
pressor has overheated. The user
should look for physical objects
that could be loose or stuck in
the ventilation openings and
clear/ dislodge. Flip the power
switch back to the “ON” posi-
tion. If the problem persists, the
user should let the unit sit for 30
minutes to see if it’s an overheat-
ing issue. If the unit still refuses to
restart after 30 minutes, the user
should contact Service Tech Team.
Allow the unit to sit for a minimum
of 30 minutes with the power off.
If the air compressor does not
come up to speed when pressing
the trigger, this may be a sign
that the unit has been stored
below 55°F (12.5°C).
If unit has been stored where
temperatures are below 55°F
(12.5°C) move the unit to a warm
environment and allow the unit
to acclimate before operation.
EXCESSIVE NOZZLE DRIPPING
SYSTEM WILL NOT TURN ON
OR HAS SHUT OFF SUDDENLY
NOTE: DO NOT USE
a chemical in the unit that is not a ByoPlanet
®
-approved product. If you encounter the issues listed below,
use the suggested troubleshooting methods. If you encounter
an issue that is not addressed in this manual, contact Service
Tech Team at
www.servicetechteam.com.
10 | ENGLISH
BYOPLANET.COM
Volts
~240V
Running AMPS
3.0
Minimum Operating
55°F (12.5°C) Allow to acclimate
Temperature
to room temperature if stored
below 55°F (12.5°C)
Frequency
50 Hz
Standard Hose Length 7 ft. (2.13 m)
Dimensions
25 3/8 in. (64 cm) H x 10 1/16 in.
(26 cm) W x 17 1/8 in. (43 cm) L
Air Line Pressure
35 psi (2.4 Bar)
Weight – Empty
43 lbs (20 kg)
Weight – Full
59 lbs (27 kg)
Shipping Weight
52 lbs (24 kg)
Flow Rate
110–130 mL/min
SPECIFICATIONS FOR 240V MODEL