ECB16 ECB18
59
OM-ECB162015006-EN-US
Trouble-shooting Methods
The following table contains all the error messages that could be shown in the multifunction
display. Please refer to the trouble shooting method for solution when the following error occurs.
Type
Error Message
Solution
Drive
Drive logic error One
If battery charge is below 10
%
, charge the battery. If battery
charge is over 30
%
, restart the forklift.
Drive logic error Three
Restart the forklift
Drive motor 3 phase wire fault
Check the polarities on drive control for a short circuit. If no,
restart the forklift.
Drive system fault
Restart the forklift
Drive module fault
Restart the forklift
Drive motor encoder fault
Check if the motor encoder is correctly connected. If so, restart
the forklift
Drive module initiation sequence fault
Return the direction control switch to Neutral and restart the
forklift
Restart the forklift
Drive module heat sensor fault
Restart the forklift
Lift
Lift logic error one
If battery charge is low, charge the battery. If battery charge is
normal, restart the forklift
Lift logic error three
If load exceeds the rated capacity, stop lifting; otherwise restart
the forklift.
Lifting motor 3 phase fault
Check the polarities on the lifting control for a short circuit. If no,
restart the forklift.
Lifting motor encoder fault
Check if the motor encoder is correctly connected. If yes, restart
the forklift.
Lifting motor heat sensor fault
Restart the forklift
Lifting motor current sensor fault
Restart the forklift
Please check the lifting system
Accelerator
Accelerator pedal false triggering
Check if the accelerator will return normally. Otherwise contact
the after sales service.
Accelerator pedal fault
Contact the after sales service
Others
Main contactor open circuit
Check that the main contactor closes.
Electrical relay fault
Restart the forklift
Please check gear
Switch off the forklift, return the lever to Neutral position and
restart the forklift
CAN error
Restart the forklift
Battery
Total voltage error
Restart the forklift
Temperature
Drive module overheating
Shut down the forklift for 5 minutes and restart it.
Drive motor overheating
Lifting module overheating
Lifting motor overheating
* After taking the recommended measures, contact the service personnel if the error message
reappears and repeats more than 3 times.
https://www.forkliftpdfmanuals.com/
Summary of Contents for ECB16
Page 2: ...https www forkliftpdfmanuals com...
Page 3: ...OPERATOR MANUAL OM ECB162015006 EN US ECB16 ECB18 https www forkliftpdfmanuals com...
Page 9: ...ECB16 ECB18 9 OM ECB162015006 EN US https www forkliftpdfmanuals com...
Page 10: ...https www forkliftpdfmanuals com...
Page 14: ...https www forkliftpdfmanuals com...
Page 33: ...ECB16 ECB18 23 OM ECB162015006 EN US https www forkliftpdfmanuals com...
Page 34: ...https www forkliftpdfmanuals com...
Page 40: ...https www forkliftpdfmanuals com...
Page 48: ...https www forkliftpdfmanuals com...
Page 79: ...ECB16 ECB18 69 OM ECB162015006 EN US https www forkliftpdfmanuals com...
Page 80: ...https www forkliftpdfmanuals com...
Page 86: ...https www forkliftpdfmanuals com...
Page 109: ...ECB16 ECB18 99 OM ECB162015006 EN US https www forkliftpdfmanuals com...
Page 110: ...https www forkliftpdfmanuals com...
Page 115: ...https www forkliftpdfmanuals com...
Page 116: ...OPERATOR MANUAL ECB16 ECB18 https www forkliftpdfmanuals com...