3.

 

POSITIONING OF 
THE PLANT 

 
The plant must be placed in a non-
freezing  environment  on  an  even 
foundation so that the water in the 
reservoir  does  not  overflow  when 
the tank is full. 
the  foundation  must  be  able  to 
stand  a  load  of  approx.  100  kg, 
which is the plant weight when full. 
The plant is furnished with  casters, 
so  if  you  wish  to  be  able  to  move 
the  plant,  you  should  keep  the 
foundation even and solid. 
The  outside  measures  of  the  plant 
are  (WxDxH):  350x560x750  mm, 
but when positioning the plant you 
should consider that the cover shall 
be demounted during maintenance 
work.  Either  you  must  calculate 
with  an  additional  370  mm  in 
height  to  be  able  to  lift  the  cover, 
or  it  should  be  possible  to  roll  the 
plant out for servicing (e.g. place it 
under a table or equal). 
You should also make room on the 
back  of  the  plant  for  the  water  in-
stallation;  especially  you  should 
take  into  account  the  outlet  hose 
from the plant. The hose may nev-
er be bent! 
Positioning  of  the  plant  must  be 
done  in  a  way  so  that  the  air  in-
take  on  the  front  never  gets  cov-
ered. 
There must also be room in front of 
the  plant,  so  that  it  is  possible  to 
freely  read  the  flow,  and  the  suc-
tion of the high-pressure pump can 
take  place  without  obstruction.  Al-
so it should be  possible to pull out 
the  plant  in  connection  with 
maintenance. 
In case of a stoppage, the reservoir 
may  overflow.  Therefore  there 
should  always  be  a  drain  in  the 
immediate  vicinity  of  the  plant  so 
that the overflowing water does not 
cause damage. 
If  there  is  no  floor  drain  near  the 
plant,  installing  the  plant  is  at 
your own risk. 
 

4.

 

WATER QUALITY 

 
The  raw  water,  which  is  to  be 
treated  in  the  BWT  PERMAQ

®

 

Compact  51  plant,  must  be  sof-
tened  drinking  water  quality  with 
maximum  500  mg/l  TDS.  Max. 
raw  water  temperature  is  25  °C. 
The  plant  is  adjusted  at  10  °C  in 
our factory. 
The raw water may maximum con-
tain: 
* Fe: 

 0.05 mg/l 

* Mn: 

 0.02 mg/l 

* Cl:  

 0.1 mg/l 

* Turbidity:      1.0 NTU 
* SDI: 

 3.0 

%/min

 

* KMnO4:       10 mg/l 
If  there  are  doubts  about  the  raw 
water  composition,  a  water  analy-
sis  must  be  made.  The  plant  must 
be connected to a raw-water pres-
sure  of  minimum  2  bar  and  maxi-
mum  7  bar.  The  quality  of  the 
treated  water  will  be  less  than  20 
µS/cm at 10 °C. 
 

5.

 

WATER CONNEC-
TIONS 

 
Note!  All  water  connections  must 
be in compliance with local regula-
tions. 

5.1

 

Connection of raw 
water (inlet water) 

 

BWT sell complete assembly kits for 
BWT PERMAQ

®

 Compact 51. 

On the inlet side you must fit a ball 
valve so that the water may be cut 
off  during  maintenance  of  the 
plant. 
Install  a  ½”  flexible  pressure  hose 
on  the  pre-filter  of  the  plant  (A-
Figure  2).  The  opposite  end  shall 
be  connected  to  the  raw-water 
supply. 
The  best  operating  result  is  ob-
tained  by  connecting  to  minimum 
¾”  raw-water  pipe.  That  reduces 
the  drop  in  pressure  to  the  plant. 
With  a  too  small  raw-water  con-
nection, there will be a risk of out-

age  on  the  plant  due  to  lacking 
water  pressure,  e.g.  when  rinsing 
out  the  membranes  at  start-up  of 
the  plant.  Note!  Fit  the  built-in 
flowmeter to the cabinet. 

5.2

 

Connection of per-
meate (treated wa-
ter) 

 

Fit  a  ¾"  flexible  pressure  hose  to 
the  transport  pump  (B-Figure  2). 
The opposite end shall be connect-
ed  to  the  consumer  of  the  treated 
water  or  pipe  connection  which  is 
led to  consumer of the treated wa-
ter. Note! Totally desalinated water 
may  speed  up  corrosion.  There-
fore, always use non-corrosive pip-
ing  for  the  treated  water,  e.g. 
stainless steel or PVC. 

5.3

 

Connection of out-
let hose 

 

Start  by  dismounting  the  “bent” 
blue hose which is fitted on the out-
let valve (B-Figure 3). 
Install  the  supplied  10  mm  plastic 
hose to outlet valve (B-Figure 3).  It 
is  important  that  the  hose  is 
pressed all the way down. The op-
posite  end  shall  be  connected  to 
outlet.  The  hose  may  not  be  led 
down into the outlet water, though, 
since  the  water  may  risk  getting 
sucked  back  into  the  plant  during 
standstill.  Note!  The  outlet  hose 
may never be bent or in any other 
way  obstructed,  as  this  would 
damage the plant membrane. 

5.4

 

Connection of over-
flow hose 

 

On  the  back  of  the  plant,  on  the 
overflow  nozzle  (C-Figure  2),  you 
shall  connect  a  ½”  plastic  hose  to 
the  floor  drain  or  another  subja-
cent drain. This overflow is a safety 
overflow in case an fault occurs on 
the level switch of the plant and the 
reservoir  tank  as  a  consequence 
gets filled to overflowing. 

Summary of Contents for PERMAQ COMPACT 51

Page 1: ...BWT PERMAQ COMPACT 51 Reverse Osmosis Plant Installation and Operating manual UK For You and Planet Blue...

Page 2: ...UK 2...

Page 3: ...e treated water is higher than 20 S cm 9 9 2 3 Alarm Low raw water pressure 10 9 2 4 Alarm Transport pump 10 9 2 5 Indication Level low 11 9 2 6 Alarm Level high 11 9 2 7 The plant is not operating 12...

Page 4: ...d in our factory Your BWT PERMAQ Compact 51 plant is furnished with casters in a stainless frame That means that the plant can be placed e g under a table and pulled out for easy ser vicing Your BWT P...

Page 5: ...e plant must be connected to a raw water pres sure of minimum 2 bar and maxi mum 7 bar The quality of the treated water will be less than 20 S cm at 10 C 5 WATER CONNEC TIONS Note All water connection...

Page 6: ...ead the entire section 7 1 and 7 2 before adjustment is commenced Outlet amount must be adjusted and the suitable outlet amount on your plant depends on the raw water quality A too high water re cover...

Page 7: ...tank is full NB Do not touch the level switch Create a large consumption of treated water to get the air out of the pump Check that the transport pump G Figure 3 starts up automatically Check that th...

Page 8: ...e BWT PERMAQ Compact 51 plant is produced and designed for a minimum of servicing and maintenance However there are certain functions which should be checked regularly Maintenance intervals should be...

Page 9: ...UK 9 9 2 Troubleshooting This section deals with the problems that may arise on the plant 9 2 1 The plant capacity has dropped 9 2 2 The quality of the treated water is higher than 20 S cm...

Page 10: ...UK 10 9 2 3 Alarm Low raw water pressure 9 2 4 Alarm Transport pump...

Page 11: ...UK 11 9 2 5 Indication Level low 9 2 6 Alarm Level high...

Page 12: ...UK 12 9 2 7 The plant is not operating...

Page 13: ...UK 13 9 2 8 Alarm The transport pump stops and starts 9 2 9 Hard water is measured at the soft water tap option...

Page 14: ...condition Section 9 2 4 ALARM Too low raw water pressure Nothing is working permanent condition Section 9 2 3 Too low raw water pressure HP pump stopped TP pump is working Automatic restart 3 times if...

Page 15: ...6 Transport pump 10 TECHNICAL SPECIFICATION 10 1 Technical specifications BWT PERMAQ Compact 51 Tag number Designation Type data P1 High pressure pump 14 bar 1x230V 0 64kW P2 Transport pump 1x230V 0...

Page 16: ...V 230 Power consumption kW 1 5 Electricity frequency Hz 50 Pipe inlet diameter Concentrate outlet diameter 10mm hose Permeate outlet diameter Height mm 750 Depth mm 560 Width mm 350 Max water temp C...

Page 17: ...oise until the warm water has run into the plant Then operate the plant in this way for 20 30 min until the plant components mem branes pumps are heated to approx 40 C Replace the wa ter in the bucket...

Page 18: ...t also be installed so that the V cup seal has to be placed at the top when the membrane is fitted inside the membrane pipe When the membrane has been replaced and the end plate has been refitted with...

Page 19: ...3 ANNEX 13 1 P I diagram 13 2 Layout drawings 13 3 Wiring diagram 13 4 Start up test 13 5 Operating journal 13 6 Spare parts list BWT PERMAQ Compact 51 13 7 Spare parts drawing 13 8 Declaration of con...

Page 20: ...UK 20 13 1 P I Diagram...

Page 21: ...UK 21 13 2 Layout Drawings...

Page 22: ...UK 22...

Page 23: ...UK 23...

Page 24: ...UK 24...

Page 25: ...UK 25 13 3 Wiring Diagrams...

Page 26: ...UK 26...

Page 27: ...UK 27...

Page 28: ...of technician Date Time consumption for the start up hours Start up test The start up test sheet must be completed and filed together with the operating journal Test of raw water YES Time controlled...

Page 29: ...arts List BWT PERMAQ Compact 51 Control of rawwater Pressure switch PS1 every 6 month Check up for leaks every month Softening plant option Hardness dH Raw water Raw water tempera ture C Raw water pre...

Page 30: ...1404681 13 Push in fitting 14 mm elbow 1 454090014 3 years 14 Bypass valve 1 200721030 15 High pressure motor 451202495 16 High pressure pump 451202490 17 Coupling for high pressure pump 451202485 18...

Page 31: ...451404215 2 years 36 Push in fitting 14x elbow 1 454090013 3 years 36A Push in fitting 10x elbow 1 454091010 3 years 37 End plate 1 451404112 3 5 years Miscellaneous 10 mm plastic hose 1 m 454001010 3...

Page 32: ...UK 32 13 7 Spare Parts Drawing...

Page 33: ...600 900 bwt bwt dk www bwt dk herewith declares that BWT PERMAQ Compact 51 is in conformity with the provisions of the Machinery Directive directive 2006 42 EC is in conformity with the provisions of...

Page 34: ...________________________ ________________________________________________________________________________ ________________________________________________________________________________ _____________...

Page 35: ...________________________ ________________________________________________________________________________ ________________________________________________________________________________ _____________...

Page 36: ...00 Fax 33 1 4922 45 45 E Mail bwt bwt fr BWT Belgium NM Leuvensesteenweg 633 B 1930 Zaventem Tel 32 2 758 03 10 Fax 32 2 758 03 33 E Mail bwt bwt be BWE esk Republika s r o Lipovo 196 Cestlice CZ 251...

Reviews: