BWT Liff Powermag PM100S Installation & Operating Instruction Manual Download Page 6

 
 

 

Key to LCD Display 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  Running Temperature: Temperature 

reading from the thermistor on the 
outlet pipework 
 

  Coil Current: Operating current of 

electromagnet 
 

  Hours Run: Total hours of coil 

operation since installation 
 

  Set Temperature: Maximum 

temperature setting for thermistor 
circuit 
 

  Coil Status: Current status of the coil  

- Coil Active when operational  
- Coil Inactive when thermistor set 
temperature is achieved 
 

  Activity LED Display: Visual display of 

coil activity 
- LED will run left to right when active 
- LED will halt when inactive 
- LED will illuminate fully when a fault 
is present 

Isolation 

Valve 

Isolation 

Valve 

LED 

Display 

Activity 

LED 

Display 

Isolation 

Switch 

Powermag 

230V 50Hz Supply 

Thermistor  

Attach to the pipe surface downstream of 
the device using cable tie or similar 

Use for cold water only 

Thermistor is a safety and efficiency device 
for cold water systems and will render the 
coil inactive when water stops flowing by 
detecting an increase in the standing water 
temperature in the pipework 

 

 

Powermag coil flying lead length 

supplied: 4.5m (approx.) 

Thermistor lead length supplied: 

2.5m (approx.) 

Summary of Contents for Liff Powermag PM100S

Page 1: ...Installation Operating Instruction Manual...

Page 2: ...2 Contents 1 General Notes 3 2 Installation 4 3 Electrical Notes 7 4 Troubleshooting Guide 9 5 Spare Parts List 9 6 Specifications 10 7 Warranty Information 11...

Page 3: ...g deposits of hard scale within the system The Powermag physical water conditioner does not introduce sodium or any other chemicals into the water and therefore the water remains potable Physically co...

Page 4: ...ows and fittings in order to adequately locate the device we recommend keeping this to a minimum The device is manufactured from stainless steel tubing and as such is resistant to corrosion We recomme...

Page 5: ...om a central water tank After a booster pump Directly on the cold mains supply where all outlets are mains fed Isolation Valve Isolation Valve Isolation Valve Pump Powermag Pipe Supports Water Tank Is...

Page 6: ...activity LED will run left to right when active LED will halt when inactive LED will illuminate fully when a fault is present Isolation Valve Isolation Valve LED Display Activity LED Display Isolation...

Page 7: ...l Notes Identifying the main components Control PCB Display Power Supply PCB Assembly inc smoothing capacitor and bridge rectifier MCB Coil DC Supply MCB Mains AC Supply Power Transformer Connection T...

Page 8: ...marked use brown cable use blue cable E use green yellow cable NOTE a spare Earth terminal is available on the left of the terminal block Connect thermistor cable to 2 central terminals marked TEMP or...

Page 9: ...ntrol PCB Display Mains MCB tripping Fault on transformer Test and replace transformer Coil DC supply MCB tripping Fault on coil Test and replace coil Panel temperature high Loose connections on power...

Page 10: ...30 Frictional loss bar 0 2 0 2 0 2 0 2 0 2 0 2 Max water temperature C 25 25 25 25 25 25 Max pressure bar 16 16 16 16 16 16 Electrical Specification NOTE MCB ratings are maximum safety ratings Actual...

Page 11: ...which it was not designed or intended Incorrect installation e g failure to follow instructions or advice given by BWT UK or its representatives and failure to follow industry guidelines or standard p...