2. Installation 

 

Powermag must be installed by a professional installer 

 

The  device  should be  installed  directly  in-line  on  pipework  in any  of  the 
following materials; stainless steel, galvanized steel, copper or plastic. 

To  ensure  that  the  device  is  adequately  supported  and  does  not  place 
excessive  strain  on  the  existing  pipework,  we  recommend  using 
additional  support  brackets  (not  supplied)  on  the  inlet  and  outlet 
pipework.  The  device  can  be  installed  in  either  vertical  or  horizontal 
orientation to suit your existing pipework and while it may be necessary 
to  install  additional  pipework,  elbows  and  fittings  in  order  to  adequately 
locate the device we recommend keeping this to a minimum. 

The  device  is  manufactured  from  stainless  steel  tubing  and  as  such  is 
resistant to corrosion. 

We recommend the use of isolation valves before and after the device to 
facilitate any service or maintenance work that may be required. 

The  Powermag  control  panel  should  be  connected  to  a  suitable  13A 
fused  switched  spur.  Please  refer  to  the  product  specification  data  to 
ensure you have a suitable spur available. 

The  spur  must  incorporate  an  accessible  isolation  switch  to  enable 
maintenance or repair of the device. 

Under  no  circumstances  should  the  Powermag  coil  assembly  be 
connected  directly  to  any  mains  power  supply.  Always  connect  the  coil 
assembly to the control panel supplied with the device. 

 

 

Summary of Contents for Liff Powermag PM100S

Page 1: ...Installation Operating Instruction Manual...

Page 2: ...2 Contents 1 General Notes 3 2 Installation 4 3 Electrical Notes 7 4 Troubleshooting Guide 9 5 Spare Parts List 9 6 Specifications 10 7 Warranty Information 11...

Page 3: ...g deposits of hard scale within the system The Powermag physical water conditioner does not introduce sodium or any other chemicals into the water and therefore the water remains potable Physically co...

Page 4: ...ows and fittings in order to adequately locate the device we recommend keeping this to a minimum The device is manufactured from stainless steel tubing and as such is resistant to corrosion We recomme...

Page 5: ...om a central water tank After a booster pump Directly on the cold mains supply where all outlets are mains fed Isolation Valve Isolation Valve Isolation Valve Pump Powermag Pipe Supports Water Tank Is...

Page 6: ...activity LED will run left to right when active LED will halt when inactive LED will illuminate fully when a fault is present Isolation Valve Isolation Valve LED Display Activity LED Display Isolation...

Page 7: ...l Notes Identifying the main components Control PCB Display Power Supply PCB Assembly inc smoothing capacitor and bridge rectifier MCB Coil DC Supply MCB Mains AC Supply Power Transformer Connection T...

Page 8: ...marked use brown cable use blue cable E use green yellow cable NOTE a spare Earth terminal is available on the left of the terminal block Connect thermistor cable to 2 central terminals marked TEMP or...

Page 9: ...ntrol PCB Display Mains MCB tripping Fault on transformer Test and replace transformer Coil DC supply MCB tripping Fault on coil Test and replace coil Panel temperature high Loose connections on power...

Page 10: ...30 Frictional loss bar 0 2 0 2 0 2 0 2 0 2 0 2 Max water temperature C 25 25 25 25 25 25 Max pressure bar 16 16 16 16 16 16 Electrical Specification NOTE MCB ratings are maximum safety ratings Actual...

Page 11: ...which it was not designed or intended Incorrect installation e g failure to follow instructions or advice given by BWT UK or its representatives and failure to follow industry guidelines or standard p...