461-8000-AC
3
SERIES FEATURE
The “461” series of receivers feature built-in repeating capability. They will listen for all transmissions from
the control transmitter, perform commands if necessary and pass all commands on to any receiver within
range to help propagate communication over widespread areas.
INSTALLATION
1. DISCONNECT power from all equipment before proceeding with installation.
2. Mount the receiver in a convenient location.
3. Install relay control wiring to the terminal strip.
4. Attach rubber duck antenna or coax from external antenna to connector on side of enclosure.
5. Connect supplied power input cable to your external power source.
TERMINAL STRIP WIRING
Terminal 1
100-250 VAC Power Input
Terminal 2
100-250 VAC Power Input
Terminal 3
CH1 Dry Contact Input (Common)
Not used on this model
Terminal 4
CH1 Dry Contact Input
Terminal 5
CH2 Dry Contact Input (Common)
Terminal 6
CH2 Dry Contact Input
Terminal 7
N/O Relay 1
Terminal 8
C Relay 1
Terminal 9
N/C Relay 1
Terminal 10
N/O Relay 2
Terminal 11
C Relay 2
Terminal 12
N/C Relay 2
Terminal 13
N/O Relay 3
Terminal 14
C Relay 3
Terminal 15
N/C Relay 3
Terminal 16
N/O Relay 4
Terminal 17
C Relay 4
Terminal 18
N/C Relay 4