461-8000-AC
6
RELAY OPERATION
Button Depressed
OR Input Activated
Relay Action
1
Relay 1 Energizes, Maintained Momentary
2
Relay 2 Energizes, Maintained Momentary
3
Relay 3 Energizes, Maintained Momentary
4
Relay 4 Energizes, Maintained Momentary
RELAY & FREQUENCY SETUP
The unit is shipped from the
factory with SEL1 switches in
the open positions. All four
relays will operate as
maintained momentary and unit
is receiving commands on
frequency one. If you wish to
change these default settings,
follow the instructions below:
1. *IMPORTANT*
Disconnect power from
unit.
2. Remove top cover.
3. Select desired relay
operation and/or
frequency using the
table.
4. Reattach cover.
5. Reconnect power to
unit.
6. Programming is
complete.
RELAY CONFIGURATION
SEL1
SW#
OPEN
CLOSED
SW1
Relay #1 momentary
(default)
Relay #1 toggle/latch
SW2
Relay #2 momentary
(default)
Relay #2 toggle/latch
SW3
Relay #3 momentary
(default)
Relay #3 toggle/latch
SW4
Relay #4 momentary
(default)
Relay #4 toggle/latch
Maintained Momentary
– Relay mimics button or input – when depressed or closed,
relay will be energized; when released, relay de-energizes.
Toggle Latch
– Relay changes and holds its state each time the corresponding
button or input is depressed or closed.
FREQUENCY SETUP
NETWORK
FREQUENCY
SW5
SW6
SW7
1
(default)
OPEN
OPEN
OPEN
2
CLOSED
OPEN
OPEN
3
OPEN
CLOSED
OPEN
4
CLOSED
CLOSED
OPEN
5
OPEN
OPEN
CLOSED
6
CLOSED
OPEN
CLOSED
7
OPEN
CLOSED
CLOSED
8
CLOSED
CLOSED
CLOSED
SAFETY DELAY TIMER
TIME
SW8
SW9
5 Sec (
default
)
OPEN
OPEN
30 Sec
CLOSED
OPEN
60 Sec
OPEN
CLOSED
90 Sec
CLOSED
CLOSED
The safety delay timer allows the unit to keep the relay active during periods of high
interference or bad reception. This is the amount of time that a signal must be lost
before turning off the relay. This also is a safety feature to turn off the relay if the
relay off code is missed due to bad signal.