441-HH-1
5
TRANSMITTING MODE SET-UP
Please read through these instructions completely before beginning programming procedure!
The transmitter can be set to be in a standard transmission mode or in a repeater mode where all
receivers will repeat the transmission.
NOTE: When setting up the transmitting mode, the LED will cycle through the indications for all the other
set up options (frequency, relay selection, power level) before it gets to the point where you can select the
transmission mode That’s why in the directions below, you’ll see that you have to hold the button for 14
seconds until the LED starts blinking
GREEN
/
RED
quickly.
To select transmission mode:
1. Remove one battery from the transmitter
2. Press and hold Button 1 while inserting the battery
3. Continue holding Button 1 for 14 seconds until the LED cycles through the previous setup
options and starts blinking
GREEN/RED
quickly.
4. Press button once for standard mode or twice for repeating mode.
5. LED will turn
RED
if standard mode selected or
GREEN
if repeater mode selected.
6. If no button is pressed for 10 seconds, the LED will illuminate to show the current
transmission mode.
Once the transmission mode has been selected, the LED will continue to illuminate
RED
(standard mode)
or
GREEN
(repeater mode) during all future transmissions.
NOTES ON TRANSMISSION MODE
The standard transmission mode is best for situations where quick button response is needed. This type
of transmission is typically used when you’ll be watching what you’re controlling, so repeating is not
necessary.
For repeating mode there is a short delay added to the button commands to allow the system to repeat
between multiple receivers without collision. This type of system is usually something where many units
spread out over a lar
ge area need to be controlled simultaneously and response speed isn’t a priority.
Both types of transmission can be used simultaneously in the same system although repeating
transmissions could cause some lag in the standard transmissions.
APPROVALS
United States (FCC)
MCQ-XB900HP
Canada (IC)
1846A-XB900HP
Australia
RCM
Brazil
ANATEL 3727-12-1209