38-2000-DC
6
RELAY OPERATION
Button Depressed
OR Input Activated
Relay Action
1
Relay 1 Energizes, Maintained Momentary
2
Relay 2 Energizes, Maintained Momentary
3
Relay 3 Energizes, Maintained Momentary
4
Relay 4 Energizes, Maintained Momentary
RELAY & FREQUENCY SETUP
The unit is shipped from the factory
with SEL1 switches in the open
positions. All four relays will operate as
maintained momentary and unit is
receiving commands on frequency
one. If you wish to change these
default settings, follow the instructions
below:
1. *IMPORTANT*
Disconnect power from unit
2. Remove top cover.
3. Select desired relay operation
and/or frequency using the
table.
4. Reattach cover.
5. Reconnect power to unit.
6. Programming is complete.
RELAY CONFIGURATION
SEL1
SW#
OPEN
CLOSED
SW1
Relay #1 momentary
(default)
Relay #1 toggle/latch
SW2
Relay #2 momentary
(default)
Relay #2 toggle/latch
SW3
Relay #3 momentary
(default)
Relay #3 toggle/latch
SW4
Relay #4 momentary
(default)
Relay #4 toggle/latch
Maintained Momentary
– Relay mimics button or input –
when depressed or closed, relay will be energized; when
released, relay de-energizes.
Toggle Latch
– Relay changes and holds its state each time
the corresponding button or input is depressed or closed.
FREQUENCY SETUP
NETWORK
FREQUENCY
SW5
SW6
SW7
1 (default)
OPEN
OPEN
OPEN
2
CLOSED
OPEN
OPEN
3
OPEN
CLOSED
OPEN
4
CLOSED
CLOSED
OPEN
5
OPEN
OPEN
CLOSED
6
CLOSED
OPEN
CLOSED
7
OPEN
CLOSED
CLOSED
8
CLOSED
CLOSED
CLOSED
Note
– SW8 & SW9 not used on this model