37
GasAlertQuattro
Troubleshooting
Last Bump Test
Failed
If the last bump test
failed and the Force
Bump Test option is
enabled, a bump test
must be performed.
Use the MicroDock II
station to perform a bump
test, otherwise press
C
to deactivate the detector.
If you do not have a
MicroDock II, change the
bump interval in
FleetManager II, refer to
Bump Test on page 12
.
Bump Test Overdue
Screen displays
when sensors are
overdue for a bump
test and the
Force
Bump
test option is
disabled.
Apply gas directly or use
the MicroDock II, other-
wise press
C
to enter
normal operation with the
bump test overdue.
Refer to
Bump Test on
page 12
.
Force Bump Test
If the
Force Bump
Test
option is
enabled, the sensors
must be bump tested
to enter normal
operation.
Apply gas immediately or
use the MicroDock II
station, otherwise press
C
to deactivate the
detector.
Refer to
Bump Test on
page 12
.
BW recommends to bump test the sensors before each
day’s use to confirm their ability to respond to gas by
exposing the detector to a gas concentration that exceeds
the alarm setpoints.
Error Screen
Problem
Solution
Error Screen
Problem
Solution
H
2
S
CO
LEL
O
2
Last Bump Test
FAILED
waiting... 272
Press to accept
H
2
S
CO
LEL
O
2
Bump Test due
Use MicroDock or
apply gas now
Press to ignore
waiting... 272
H
2
S
CO
LEL
O
2
Force Bump Test
Use MicroDock or
apply gas now
Press to shut off
waiting... 272