background image

GasAlertClip English Instruction Sheet 

D2087/2 Page 2  

Trimmed and folded dimensions: 4.125 (w) x 5.875 (H)  

 

Display Features 

 

 

Maximum exposure under alarm 

B

 

High and low alarm setpoints 

C

 

Self-test status 

Gas monitored 

B   E 

Alarm condition 

F   G 

Life-remaining clock 

A   G 

Time since maximum exposure 

 

Life-Remaining Clock 

The life-remaining clock indicates how much longer the detector will 
operate. The display shows the countdown of remaining months, then days, 
and then hours. 

 

 

Gas Alarm Setpoints (factory standard) 

Model 

Low Alarm Setpoint 

High Alarm Setpoint

GasAlertClip O

2

19.5% 

 

23.5%

GasAlertClip CO 

35 ppm 

200 ppm 

GasAlertClip H

2

10 ppm 

15 ppm 

GasAlertClip SO

2

5 ppm 

10 ppm 

 

Note: May be equipped with customer specified alarm setpoints. Press the 
test button to display alarm setpoints at any time. 

Gas Alarms 

Low Gas Alarm 

Display 

Audible Alarm 

Visual Alarm 

 

 

Slow beeps 
(1 beep every 
2 seconds) 

Slow vibrations*  

Slow flashes 
(1 flash every 
2 seconds) 

 

High Gas Alarm 

Display 

Audible Alarm 

Visual Alarm 

 

 

Fast beeps 
(1 beep every 
second) 

Fast vibrations*  

Fast flashes 
(1 flash every 
second) 

 

*Vibrator models only. 

When gas levels return to the acceptable range, the gas alarm stops. 

Note: The life of the battery decreases rapidly under alarm conditions. 

Maximum Gas Exposure 

The detector records the maximum gas exposure under alarm condition, 
and begins calculating the number of hours since the maximum exposure 
occurred. 

For each gas level further from the acceptable range, the detector resets the 
maximum gas exposure to the new level and resets hours to 0. After 
24 hours of gas reading in the acceptable range, the detector resets both 
values to 0. 

Viewing Maximum Gas Exposure 

Press the Test button within 24 hours of receiving a gas alarm.  

• 

If the display shows 

u

 , the detector tells you: 

1. 

The low and high alarm setpoints: 

 

 

 

 

 

2. 

The maximum gas exposure and the hours since exposure: 

 

 

 

 

 

• 

If the display shows 

Test 

when the button is pressed, the display 

shows the gas exposure information at the end of the self-test. 

For exposures above the measuring range, the display shows 

OL

Reviews: