Product installation
The correct installation method can avoid measurement errors, and the following points should
be taken when installing the sensor:
First of all, to ensure that the sensor mounting surface is completely close to the measured
surface, the measured surface should be as horizontal as possible, and there should be no angle
shown in Figure A and Figure C. The correct installation method is shown in Figure B and Figure D.
Measured surface
The mounting
surface is
uneven and
produces an
angle
Measured surface
The mounting
surface is
uneven and
produces an
angle
C
D
Measured surface
Measured surface
A
B
Secondly, the bottom edge of the sensor and the axis of the object to be measured cannot be generated at an
angle as shown in Figure E. The bottom edge of the sensor should be kept parallel or orthogonal to the axis of
rotation of the object to be measured. This product can be installed horizontally or vertically (vertical installation
requires customization), and the correct installation method is shown in Figure F.
Finally, the mounting surface of the sensor and the surface to be measured must be fixed, the
contact is flat, and the rotation is stable. The measurement error caused by acceleration and vibration
should be avoided.