Operation
Butzbach GmbH Industrietore
Originalbedienungsanleitung SECTIOLITE_V1
24/02/2021
27
Diagram 8 Electrical cylinders for doors with anti-burglary protection
Legend
01 Mounting screws
02 Holder
03 Locking bolt
✔
Spaces with door systems with anti-burglary devices (WK3) must have a separate second exit.
✔
This only applies to doors in WK3 version!
✔
For emergency operation, the electromechanical locking cylinder must be dismantled as follows:
1.
Remove the mounting screws
01
.
2.
Remove the locking bolt
03
including the holder
02
.
3.
Open the door with the emergency operation. Pay attention to the description in the operating
manual!
7.5.2 Hand chain (GfA drive system)
✔
Extraordinary situation, e.g. power outage
✔
The hand chain is located directly next to the drive system.
✔
Manual tension: < 390 N! Otherwise, there is the risk of property damage!
✔
Important!
Make sure you have stable footing!
1.
Before you operate the hand chain (emergency operation / manual operation), pull the red wire rope
(location: at the drive system next to the hand chain).
2.
The hand chain must lock into place as heard with a click!
3.
Determine the direction to pull for door OPEN / door CLOSE from the sticker on the guide rail.