Control and display elements
Butzbach GmbH Industrietore
Originalbedienungsanleitung SECTIOLITE_V1
24/02/2021
21
6.1.3.3
Control unit BDC E800 F2/F4 (frequency converter control 0.75 - 2.2kW)
Diagram 6 Control unit E800 (frequency converter control 0.75 - 2.2kW)
Topic
Description
Button ↑, 0, ↓
One control button each for the functions: Open ↑, Stop 0, Close ↓
Dial / pushbutton
Control buttons for parametrisation or requesting diagnostic information (see the
description of the BDC E800 control unit).
Main switch
To disconnect the system from the mains. It can be secured against being turned on again
with an adapter and hanging lock.
Placement
On the control cabinet
6.1.3.4
TST FU3F Control unit (frequency converter control 4kW)
Diagram 7 TST control unit
Topic
Description
Display
Displays, e.g. operating states or error messages
Button ↑, 0, ↓
One control button each for the functions: Open ↑, Stop 0, Close ↓
EMERGENCY STOP
Button
To shut the system off in emergency situations.
Important!
The system is not disconnected from the mains, use the main switch for this.
Key switch
To open the control cabinet.