Büttner Elektronik 3350785 Manual Download Page 16

7

 

  Troubleshooting 

 

7.1

 

Inverter indicators and acoustic signals

 

EN

 

BÜTTNER  ELEKTRONIK 

 HYMER E-Bike Charger

 

39

 

Input parameter

 

Voltage range

 

Description

 

Normal operation

 

11.5 V 

 14.0 V

 

 

Optimal operation

 

13.0 V 

 14.0 V

 

 

Low-voltage warning

 

11.2 V 

 10.7 V

 

Acoustic signal 2 x / pause

 

STOP Low-voltage

 

< 10.7 V +/-0.2 V

 

Inverter OFF, Acoustic signal 3 x / pause

 

RESTART Low-voltage

 

> 12.0 V +/-0.2 V

 

Inverter ON

 

 

STOP High-voltage

 

 

 

> 15,0 V

 

 

Inverter OFF, Acoustic signal 5 x / pause 

Voltages > 16 V may cause damage in the 

device even when not in operation!

 

Status

 

 

LED Inverter/ 

Extern

 

LED Check

 

 

Acoustic 

signal

 

Output 

230 V

 

Inverter Start

 

ON

 

ON (1sec)

 

1 x

 

ON

 

Normal operation

 

ON

 

OFF

 

OFF

 

ON

 

Low-voltage warning

 

ON

 

OFF

 

2 x / pause

 

ON

 

Low-voltage

 

ON

 

ON

 

3 x / pause

 

ON

 

High-voltage

 

ON

 

ON

 

4 x / pause

 

ON

 

Overtemperature

 

ON

 

ON

 

5 x / pause

 

ON

 

Overload warning

 

ON

 

OFF

 

1 x short / pause

 

ON

 

Overload

 

OFF

 

ON

 

continuous

 

OFF

 

Short-circuit

 

OFF

 

ON

 

continuous

 

OFF

 

 

 

 

 

 

Summary of Contents for 3350785

Page 1: ...ns supply with always optimal monitoring of your leisure bord battery Before the first start up the E bike Charger control must be set up Please read about this section Basic Settings on page 31 We ho...

Page 2: ...chnical Data 41 9 Warranty 44 EN Scope of delivery B TTNER ELEKTRONIK HYMER E Bike Charger 25 Quantity Description 1 E Bike Charger Control MT 5005iQ with display 200 A shunt with minus cable adaptor...

Page 3: ...mes the manufacturer and is liable accordingly Furthermore the manufactu rer s warranty is no longer applicable and a loss of warranty rights may result The E Bike Charger system is suitable for stati...

Page 4: ...ith a 30 A charging booster the bike battery and the board battery can be charged at the same time A charging booster with at least 50 A should beavailable for 2 connected E bike batteries i At the ca...

Page 5: ...Control Overall diagram EN E Bike Charger 1 control D E B IKE CHARGER ON OFF Central electrics Vehicle engine and alternator EBL D Signal E Bike Charger Shunt Starter battery Board battery B TTNER ELE...

Page 6: ...arger Control EN Pure sine inverter PowerLine PL 601 RCD device Charging sockets Mains transfer switch unit NU 2301 MT NU 2300 Charging sockets max 600 W RCD device Mains input Vehicle Mains input B T...

Page 7: ...l indicates that the charging current is provided while vehicle engine is running Display screen selection button For displaying power consumption negative sign or charge in A available capacity in Ah...

Page 8: ...p battery type acc table 1 Factory default 34 Increase value 1 Decrease value 1 Set up display brightness brighter darker save set up B TTNER ELEKTRONIK HYMER E Bike Charger 31 Battery type Battery ch...

Page 9: ...ly switched on regardless of the remote control input REMOTE OFF ON CHECK POWER TheswitchpositionREMOTEenablestheinvertertobeoperated via the remote control input The operating status of the inverter...

Page 10: ...g shunt and switches the inver ter on As a control in the display On If no arrow is displayed above the symbol the board battery will be charged first while driving until sufficient capacity is ensure...

Page 11: ...shown in the lower left corner of the dis play i Start of charging If the capacity of the board battery is suffi cient for operating mode 2 a small arrow will appear in the display above the symbol T...

Page 12: ...2 Capacity screen in Amp re hours and percentage The charging and discharging of the battery is recorded and balanced by a microprocessor Programmed characteristic cur ves and correspondingly set batt...

Page 13: ...es for charging operation mode 1 driving mode Switch on threshold 95 LiFePO4 all Pb types Switch off threshold 90 LiFePO4 all Pb types Switch on switch off threshold values for charging operation mode...

Page 14: ...pacity Increase capacity 1 1 Decrease capacity 1 Switched output OFF switching threshold capacity Increase capacity 1 1 Decrease capacity 1 Switched output ON switching threshold capacity Mode 2 Manua...

Page 15: ...there are no arrows in the display above the and D sign the board battery is below the switch on threshold see 6 Expert set up and needs to be charged first Check inverter 1 3 step switch must be in p...

Page 16: ...ow voltage 12 0V 0 2V Inverter ON STOP High voltage 15 0V Inverter OFF Acoustic signal 5 x pause Voltages 16V may cause damage in the device even when not in operation Status LED Inverter Extern LED C...

Page 17: ...d consumers i 7 3 Device protetion The inverter is internally protected against damage in the following events Low voltage The inverter switches off when the battery voltage drops below the STOP thres...

Page 18: ...0 A Contin current ventilated 240 A Max current 15 min 300A Max current 7 min 400 A Max peak current 900 A Dimension Smart Shunt mm 135 x 32 x 44 Weight 240 g Display unit Technic LCD Display with spe...

Page 19: ...e 2014 35 EU Standards DIN EN 60335 1 2012 A11 2014 DIN EN 60730 1 2017 05 VDE 0631 1 2017 05 ROHS and REACH compliant DIN EN 50581 2013 02 VDE 0042 12 2013 02 VDE 0042 12 2013 02 EG Nr 1907 2006 REAC...

Page 20: ...IN EN 55014 2 VDE 0875 14 2 2016 01 Low voltage directive 2014 35 EU standards DIN EN 60335 1 2012 A11 2014 DIN EN 60730 1 2017 05 VDE 0631 1 2017 05 ROHS und REACH compliant DIN EN 50581 2013 02 VDE...

Page 21: ...period granted from the date of purchase Excluded from the warranty EN Damages caused by non compliance with the instructions in the user ma nual Damage caused by reverse polarity overcurrent overvol...