7  Troubleshooting 

 

Please note the table below for initial remedial measures

 

in the event of charging problems with your E-bike batteries.

 

EN

 

BÜTTNER  ELEKTRONIK 

 HYMER E-Bike Charger

 

38

 

Fault

 

Cause

 

Solution

 

Display of E-Bike 

Charger control 

without screen

 

 

Switch-on display by short 

push on the right button

 

 

No charging of the 

E-bike batteries on 

mains supply at the 

camp site

 

Check mains input 

RCD device

 

 

The switch position must be at the top.

 

If this device can no longer be switched on / releases 

again, switch off / unplug all 230 V consumers or 

contact an electrician!

 

 

Check RCD device 

for charging 

sockets

 

 

If this device can no longer be switched on, the 

plugged in E-Bike power supply unit possibly is 

defective ! Unplug and switch-on the RCD again, 

respectively contact an electrician!

 

No charging of the 

E-bike batteries 

while driving / 

running engine

 

Charging operation 

mode 1 must be 

activated

 

 

Verification 

according to 4.1

 

 

 

Check whether  the 

display shows 

“On

” 

and 

!

 

 

If 

“On

” 

only flashes and there are no arrows in 

the display above the 

- and 

D+ 

sign, the board 

battery is below the switch-on threshold, see 6. 

Expert set-up and needs to be charged first.

 

 

Check inverter

 

1. 3-step switch must be in position 

Remote”

, see 2.

 

 

 

2. Check inverter indicators and 

acoustic signals, see 7.1.

 

 

Check RCD 

device for 

charging sockets

 

 

If this device can no longer be switched on, the 

plugged in E-Bike power supply unit possibly is 

defective! Unplug and switch-on the RCD again, 

respectively contact an electrician!

 

No charging of the 

E-bike batteries in 

manual charging 

operation

 

Charging operation 

mode 2 must be 

activated

 

 

Verification according to 4.2.

 

 

 

Check whether 

the display 

“On

” 

and

 

 

If 

“On

” 

only flashes and there are no arrows in 

the display above the 

- and 

D+ 

sign, the board 

battery is below the switch-on threshold, see

 

6. Expert set-up and needs to be charged first.

 

 

Check inverter

 

1. 3-step switch must be in position 

Remote”

, see 2.

 

 

 

2. Check inverter indicators and 

acoustic signals, see 7.1.

 

 

Check RCD 

device for 

charging sockets

 

 

If this device can no longer be switched on, the 

plugged in E-Bike power supply unit possibly is 

defective! Unplug and switch-on the RCD again, 

respectively contact an electrician!

 

 

 

 

 

 

Summary of Contents for 3350785

Page 1: ...ns supply with always optimal monitoring of your leisure bord battery Before the first start up the E bike Charger control must be set up Please read about this section Basic Settings on page 31 We ho...

Page 2: ...chnical Data 41 9 Warranty 44 EN Scope of delivery B TTNER ELEKTRONIK HYMER E Bike Charger 25 Quantity Description 1 E Bike Charger Control MT 5005iQ with display 200 A shunt with minus cable adaptor...

Page 3: ...mes the manufacturer and is liable accordingly Furthermore the manufactu rer s warranty is no longer applicable and a loss of warranty rights may result The E Bike Charger system is suitable for stati...

Page 4: ...ith a 30 A charging booster the bike battery and the board battery can be charged at the same time A charging booster with at least 50 A should beavailable for 2 connected E bike batteries i At the ca...

Page 5: ...Control Overall diagram EN E Bike Charger 1 control D E B IKE CHARGER ON OFF Central electrics Vehicle engine and alternator EBL D Signal E Bike Charger Shunt Starter battery Board battery B TTNER ELE...

Page 6: ...arger Control EN Pure sine inverter PowerLine PL 601 RCD device Charging sockets Mains transfer switch unit NU 2301 MT NU 2300 Charging sockets max 600 W RCD device Mains input Vehicle Mains input B T...

Page 7: ...l indicates that the charging current is provided while vehicle engine is running Display screen selection button For displaying power consumption negative sign or charge in A available capacity in Ah...

Page 8: ...p battery type acc table 1 Factory default 34 Increase value 1 Decrease value 1 Set up display brightness brighter darker save set up B TTNER ELEKTRONIK HYMER E Bike Charger 31 Battery type Battery ch...

Page 9: ...ly switched on regardless of the remote control input REMOTE OFF ON CHECK POWER TheswitchpositionREMOTEenablestheinvertertobeoperated via the remote control input The operating status of the inverter...

Page 10: ...g shunt and switches the inver ter on As a control in the display On If no arrow is displayed above the symbol the board battery will be charged first while driving until sufficient capacity is ensure...

Page 11: ...shown in the lower left corner of the dis play i Start of charging If the capacity of the board battery is suffi cient for operating mode 2 a small arrow will appear in the display above the symbol T...

Page 12: ...2 Capacity screen in Amp re hours and percentage The charging and discharging of the battery is recorded and balanced by a microprocessor Programmed characteristic cur ves and correspondingly set batt...

Page 13: ...es for charging operation mode 1 driving mode Switch on threshold 95 LiFePO4 all Pb types Switch off threshold 90 LiFePO4 all Pb types Switch on switch off threshold values for charging operation mode...

Page 14: ...pacity Increase capacity 1 1 Decrease capacity 1 Switched output OFF switching threshold capacity Increase capacity 1 1 Decrease capacity 1 Switched output ON switching threshold capacity Mode 2 Manua...

Page 15: ...there are no arrows in the display above the and D sign the board battery is below the switch on threshold see 6 Expert set up and needs to be charged first Check inverter 1 3 step switch must be in p...

Page 16: ...ow voltage 12 0V 0 2V Inverter ON STOP High voltage 15 0V Inverter OFF Acoustic signal 5 x pause Voltages 16V may cause damage in the device even when not in operation Status LED Inverter Extern LED C...

Page 17: ...d consumers i 7 3 Device protetion The inverter is internally protected against damage in the following events Low voltage The inverter switches off when the battery voltage drops below the STOP thres...

Page 18: ...0 A Contin current ventilated 240 A Max current 15 min 300A Max current 7 min 400 A Max peak current 900 A Dimension Smart Shunt mm 135 x 32 x 44 Weight 240 g Display unit Technic LCD Display with spe...

Page 19: ...e 2014 35 EU Standards DIN EN 60335 1 2012 A11 2014 DIN EN 60730 1 2017 05 VDE 0631 1 2017 05 ROHS and REACH compliant DIN EN 50581 2013 02 VDE 0042 12 2013 02 VDE 0042 12 2013 02 EG Nr 1907 2006 REAC...

Page 20: ...IN EN 55014 2 VDE 0875 14 2 2016 01 Low voltage directive 2014 35 EU standards DIN EN 60335 1 2012 A11 2014 DIN EN 60730 1 2017 05 VDE 0631 1 2017 05 ROHS und REACH compliant DIN EN 50581 2013 02 VDE...

Page 21: ...period granted from the date of purchase Excluded from the warranty EN Damages caused by non compliance with the instructions in the user ma nual Damage caused by reverse polarity overcurrent overvol...