INSTRUCTION, USE AND
MAINTENANCE MANUAL
GB
Page 13 of 43
2. Connect the black pipe (
Fig.
9 ref. 1
) and the blue
pipe (
Fig.
9 ref. 2
) on the provided quick couplings
as shown in
Figure 9
.
1
2
Fig. 9
IN CASE OF A CHANCE SUP-
PLY FAILURE, AND/OR BEFORE
ANY PNEUMATIC CONNECTIONS,
MOVE THE CONTROLS TO THE
NEUTRAL POSITION.
4 - Connect the mains pneumatic power supply by us-
ing the union placed on filter unit of the machine.
The pressurized pipe coming from the mains must
have a section of 10x19 (see
Fig.
10
).
Fig.
10
10.0 ELECTRICAL CONNECTIONS
EVEN THE TINIEST PROCEDURE
OF AN ELECTRICAL NATURE
MUST BE CARRIED OUT BY PRO-
FESSIONALLY QUALIFIED STAFF.
BEFORE CONNECTING THE MA-
CHINE MAKE SURE THAT:
• THE MAIN POWER RATING COR-
RESPONDS TO THE MACHINE
RATING AS SHOWN ON THE
MACHINE PLATE;
• ALL MAIN POWER COMPO-
NENTS ARE IN GOOD CONDI-
TION;
• THE ELECTRICAL SYSTEM
IS PROPERLY GROUNDED
(GROUND WIRE MUST BE THE
SAME CROSS-SECTION AREA
AS THE LARGEST POWER SUP-
PLY CABLES OR GREATER);
• MAKE SURE THAT THE ELEC-
TRICAL SYSTEM FEATURES A
CUTOUT WITH DIFFERENTIAL
PROTECTION SET AT 30 mA.
As envisaged by the regulations in force, the machine is
not equipped with a master circuit breaker, but simply
has a plug-socket connection to the electrical mains.
The machine is supplied with
3
mt. of free cable. A plug
corresponding to the following requirements must be
connected to the cable:
• Conformity to Norm
IEC 309
• 230 Volt – 16A
• 2P + Ground
• IP 44
7104-M009-2_B
AIKIDO.4 - AIKIDO.4FI