background image

FEATURES 

The  CABELA’S  VLR’s  sophisticated  digital  technology  allows  you  to  select  between  various  units  of 

measure and targeting modes. In addition, your CABELA’S VLR’s LCD incorporates illuminated indicators 

that advise you when the laser is active and when the battery charge is low. A summary of these features 

is presented below:

UNIT OF MEASURE OPTIONS 

The CABELA’S VLR can be used to measure distances in yards or meters. The unit of measure indicators 

are located in the upper right portion of the LCD. To select between yards and meters, look through the 

monocular, depress the “mode” button (left side of the unit underneath the Cabela’s VLR by Bushnell logo) 

and hold it down for approximately 2 seconds. If you are changing from yards to meters, a change in 

unit of measure will be indicated by the illumination of the letter M for METER indicator while the YD for 

YARD indicator is turned off. If you are changing from meters to yards, the opposite will occur. Note: The 

CABELA’S VLR will return to the last setting used, each time the unit is turned on.

TARGETING MODES

The  CABELA’S  VLR  incorporates  exclusive  targeting  modes  that  allow  you  to  adjust  the  performance 

parameters  of  the  unit  to  suit  your  specific  situation  and  environment.  The  different  targeting  modes 

available are listed below:

Standard (LCD Indicator  -  none): This setting allows most targets to be distanced up to 570 yards. Used 

for moderately reflective targets that are typical of most distancing situations.  The minimum distance in 

the standard mode is 10 yards.

5

Summary of Contents for Cabela 20-3031

Page 1: ...Model 20 3031 and 20 3131 Literature 98 0919 02 07 Instruction Manual by ...

Page 2: ......

Page 3: ...ot in use The rugged and weather resistant CABELA S VLR features popular Scan and 150 modes and includes a carrying case Scan mode provides continuous distance measurements as multiple targets in the field of view are scanned The 150 mode only captures distance measurements of objects greater than 150 yards away enabling distance measurement through foreground clutter like brush and branches The C...

Page 4: ...g conditions e g the amount of sunlight will affect the ranging capabilities of the unit The less light e g overcast skies the farther the unit s maximum range will be Conversely very sunny days will decrease the unit s maximum range OPERATIONAL SUMMARY While looking through the monocular depress the power button once to activate the in view display system LCD Aim the CABELA S VLR at a target at l...

Page 5: ... hold it down for approximately 2 seconds If you are changing from yards to meters a change in unit of measure will be indicated by the illumination of the letter M for METER indicator while the YD for YARD indicator is turned off If you are changing from meters to yards the opposite will occur Note The CABELA S VLR will return to the last setting used each time the unit is turned on TARGETING MOD...

Page 6: ...measure to targets less than 150 yards meters To select 150 Mode while looking through the monocular depress and release the mode button Note The CABELA S VLR will return to the last setting used each time the unit is turned on ILLUMINATING INDICATORS Low Battery Charge LCD Indicator When both dashes inside the battery symbol are displayed the battery is fully charged When the dashes start to fade...

Page 7: ...in the optical system These are a natural characteristic of the LCD cannot be fully eliminated in the manufacturing process and do not affect the distancing performance of the unit Dimensions Pocket Size measuring 1 5x4x2 75 inches Weight 6 8 oz Accuracy 1 yard Magnification 6x Display LCD even and odd numbers Power Source 3 volt lithium battery included FOV 320 ft 1000 yards Total Eye Relief 20mm...

Page 8: ...o the cleaning cloth never directly on the lens Trouble Shooting Table If unit does not turn on LCD does not illuminate Depress power button Check and if necessary replace battery If unit powers down display goes blank when attempting to power the laser The battery is either weak or low quality Replace the battery with a good quality lithium battery There is no reset button to clear last range rea...

Page 9: ...inger is blocking the objective lenses lenses closest to the target that emit and receive the laser pulses Make sure unit is held steady while depressing power button Make sure that the targeting mode selected is the appropriate mode for that specific situation or environment SCAN and 150 modes have different minimum distance and sensitivity to a specific target s reflectivity levels 9 ...

Page 10: ...cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which ...

Page 11: ......

Page 12: ......

Reviews: