Installing your gas hob
Bringing it all together
Installing your gas hob
20
If you require any technical guidance or find that your product is not operating as intended, a simple solution can often be found in the
Troubleshooting
section of these instructions,
•
Remove the burner caps and the adapters.
•
Use a 7 mm spanner to unscrew the injectors.
•
Replace the injector with the ones from the gas
conversion kit, with the correct diameters for the
type of gas that is going to be used, according to the
gas injector table.
Adapter
Spanner
Injector
Cup
Burner
cap
Adjusting the reduced flame position
First of all, make sure that the appliance is unplugged
from the the mains electrical supply and that the gas
feed is open. The minimum flame position is adjusted
with a flat screw located on the valve. For valves with
a flame failure safety device, the screw is located on
the side of the valve spindle as shown in the figures.
For valves without a flame failure safety device, the
screw is located inside the valve spindle as shown in
the figure. To make adjusting the flame position easier,
we recommend that you remove the control panel
(and the micro switch if your model has one) during the
alteration.
To determine the minimum position, ignite the burners
and leave them on in the minimum position. With the
help of a small screwdriver, fasten or loosen the bypass
screw by around 90 degrees. When the flame has a
length of at least 4mm, the gas is well distributed. Make
sure that the flame does not die out when passing from
the maximum position to the minimum position. Create
an artificial wind with your hand towards the flame to
see if the flames are stable.
The bypass screw must be loosened for conversion
from LPG to NG. For conversion from NG to LPG, the
bypass screw must be tightened. Make sure that the
appliance is unplugged from the mains electrical supply
and that the gas feed is open.
Valve with
flame failure
device
Bypass screw
Valve with flame failure
device
Bypass
screw
Valve without flame failure
device
Bypass screw
(Inside the
hole)
Changing the gas inlet
For some countries, the gas inlet type can be different
for NG/LPG gases. In this case, remove the current
connection components and nuts (if any) and connect
the new gas supply accordingly. In all conditions,
all components used in gas connections should be
approved by local and/or international authorities. In all
gas connections, refer to the “Assembly of gas supply
and leakage check” clause explained above.
Electrical Connection and Safety (If
available)
WARNING:
The electrical connection of this
appliance should be carried out by an authorised
service person or qualified electrician, according to the
instructions in this guide and in compliance with the
current local regulations.
WARNING:
THE APPLIANCE MUST BE
EARTHED.
•
Before connecting the appliance to the power
supply, the voltage rating of the appliance (stamped
on the appliance identification plate) must be
checked for correspondence to the available mains
supply voltage, and the mains electric wiring should
be capable of handling the appliance’s power rating
(also indicated on the identification plate).
Summary of Contents for BSH60BFCHB
Page 1: ...Instruction Manual GAS HOB BSH60BFCHI BSH60BFCHB BSH60CIHI ...
Page 4: ......
Page 5: ...1 Safety information ...
Page 10: ......
Page 11: ...Getting to know your gas hob 2 ...
Page 14: ......
Page 15: ...3 Installing your gas hob ...
Page 22: ......
Page 23: ...Usage 4 ...
Page 26: ......
Page 27: ...Care and maintenancee 5 ...
Page 32: ......
Page 33: ...6 Product support ...
Page 39: ...52331542 Contact www bush support com Helpline 0345 257 7271 ...