7 | Start-up
24
/ 52
0870S03254
_VO 0040-0080_B_-0000_IM_en
7.1.8
62B
Parameter settings
The parameters are set on the manual operating unit.
Parameter
Description
Set to
P3.7
Measuring margin of the pressure
transmitter
100 % = 0 ... 1,000 mbar
50 % = 0 ... 500 mbar
10 % = 0 ... 100 mbar
100%
P12.1
Target value source
0 = internal setting (P12.2)
1 = analog input 1
2 = analog input 2
3 = field bus
0
P12.2
Target pressure in %
50 % = 500 mbar
10 % = 100 mbar
5 % = 50 mbar
10%
Value may deviate due to
specific customer specifica-
tion!
P12.7
PID controller P reinforcement
500 %
P12.8
PID controller I time
0.3 s
P12.13
Shut off delay
20 s
P12.14
Level of the switch-on delay
1%
Tab. 2:
Parameter settings (factory settings)
Explanations of the settings can be found in
the document “Instructions for pump control”,
art. no. 0870 166 596.
NOTICE
When installing a new vacuum pump, the parameter settings of the vacuum pump must be
changed to the values according to table 2.