11 | Troubleshooting
22 / 28
Instruction Manual R5 RA 0155 A_EN_en
Problem
Possible Cause
Remedy
The machine does not start. The motor is not supplied
with the correct voltage.
• Check the power supply.
The motor is defective.
• Replace the motor.
The coupling (CPL) is defec-
tive.
• Replace the coupling
(CPL).
The machine does not reach
the usual pressure on the
suction connection.
Oil level too low.
• Top up oil.
The inlet screen (IS) is par-
tially clogged.
• Clean the inlet screen (IS).
The inlet filter cartridge (op-
tional) is partially clogged.
• Replace the inlet filter car-
tridge.
Internal parts are worn or
damaged.
• Repair the machine (con-
tact Busch).
The machine runs very noisi-
ly.
Worn coupling (CPL).
• Replace the coupling
(CPL).
Stuck vanes.
• Repair the machine (con-
tact Busch).
Defective bearings.
• Repair the machine (con-
tact Busch).
The machine runs too hot.
Insufficient cooling.
• Remove dust and dirt
from the machine.
• Check the cooling fan.
Ambient temperature too
high.
• Observe the permitted
ambient temperature.
Oil level too low.
• Top up oil.
The exhaust filters (EF) are
partially clogged.
• Replace the exhaust filters
(EF).
The machine fumes or ex-
pels oil droplets through the
gas discharge.
The exhaust filters (EF) are
partially clogged.
• Replace the exhaust filters
(EF).
An exhaust filter (EF) with o-
ring is not fitted properly.
• Ensure the correct posi-
tion of the exhaust filters
(EF) and the o-rings.
The float valve (FV) does
not work properly.
• Check float valve and the
oil return line, repair it if
necessary (contact Busch).
Abnormal oil consumption.
Oil leaks.
• Replace seals (contact
Busch).
The float valve (FV) does
not work properly.
• Check float valve and the
oil return line, repair it if
necessary (contact Busch).
The machine runs at atmos-
pheric pressure for a long
period.
• Make sure that the ma-
chine operates under vac-
uum.
The oil is black.
Oil change intervals are too
long.
• Flush the machine (con-
tact Busch).
The inlet filter (optional) is
defective.
• Replace the inlet filter.
The machine runs too hot.
• See problem "The ma-
chine runs too hot".