6 | Commissioning
18 / 36
0870201428_RA0165-0305D_O2_-0004_IM_en
6
Commissioning
WARNING
Lack of oxygen regulation knowledge.
Risk of fire!
• Installation, commissioning and maintenance must only be carried out by qualified
personnel who are informed about the applicable safety regulations and trained in the
handling of oxygen.
• Accident prevention regulations or methods must imperatively be complied with.
Seek further information:
- European Industrial Gases Association “EIGA” www.eiga.eu (EIGA SAG NL 79/04).
- Berufsgenossenschaft Rohstoffe und chemische Industrie "BG RCI”
(Merkblatt M 034 Sauerstoff).
WARNING
Machine contaminated with organic material.
Risk of fire!
If there is a suspicion that the machine or the oil is contaminated with organic material:
• The machine must be removed from service and cleaned by specialists (contact your
Busch representative).
CAUTION
During operation the surface of the machine may reach temperatures of more than
70°C.
Risk of burns!
• Avoid contact with the machine during and directly after operation.
CAUTION
Noise of running machine.
Risk of damage to hearing!
If persons are present in the vicinity of a non noise insulated machine over extended
periods:
• Make sure that ear protection is being used.
• Make sure that the installation conditions (see
) are met.
Version with water-oil heat exchanger:
• Turn on the water supply.
• If the cooling water inlet is equipped with a water bypass valve (WBV), open it for
approx. 90 seconds before the first machine start-up.
• Make sure that cooling water requirements are fully complied with, see
• Switch on the machine.
• Make sure that the maximum permissible number of starts does not exceed 12 starts
per hour. Those starts should be spread within the hour.