5 | Installation
22 / 40
0870201062_RA1000-1600B_Ex_-0007_IM_en
5.8 Flowchart
The machine safety depends on the monitoring accessories sequencing according to the
following flowchart.
Gas pressure
Gas temperature
Start
Cat. 2(i)
P < P warning?
Oil level
sufficient in oil mist
separator?
High gas pressure !
Warning:
P < P trip?
Cat. 2(i)
P < P switch point?
YES
NO
OR
YES
NO
NO
YES
YES
NO
NO
YES
Cat. 2(i)
T < T warning?
High gas temperature !
Warning:
T < T trip?
NO
YES
YES
NO
Cat. 2(i)
T < T switch point?
PSA+/0301
PS+/0301
Oil level
TSA+/0101
TS+/0101
TSA+/0104
TS+/0104
Oil temperature
T < T switch point?
T < T warning?
High oil temperature !
Warning:
T < T trip?
YES
YES
NO
NO
machine
in function?
Start the machine
NO
YES
YES
Stop button activated?
YES
NO
Stop the machine
Stop the machine
Alarm trip
OR
OR
LS-/0201
(Optional)
YES
Cat. 2(i)
T < T switch point?
NO
YES
Cat. 2(i)
T < T warning?
High gas temperature !
Warning:
YES
T < T trip?
NO
TS+/0102
TS+/0103
OR
TSA+/0102
TSA+/0103
Gas temperature
(Optional)