Maintenance | 7
0870201062_RA1000-1600B_Ex_-0007_IM_en
29 / 40
7.5 Coupling Maintenance
• Check the coupling backlash and carry out a visual check.
• Please refer to the coupling instruction manual (attached to the ATEX Accessories
Book) for detailed information in order to carry out a correct inspection and mainten-
ance.
Manufacturer: KTR Kupplungstechnik
Type: Poly PKZ
with ATEX certification
Cam section
Pocket section
Elastomer sets
Set screw
Set screw
7.6 Air Heat Exchanger Cleaning
3x
1
2
3
4