5 | Installation
10 | 40
Instruction Manual MINK MV 0500-0600 B_EN_en
5
Installation
5.1
Installation Conditions
NOTICE
Use of the machine outside of the permitted installation conditions.
Risk of premature failure!
Loss of efficiency!
●
Take care that the installation conditions are fully complied with.
~1 m
~1 m
~1 m
~1 m
Other values may apply after Busch approval
●
Make sure that the environment of the machine is not potentially explosive.
●
Make sure that the ambient conditions comply with the
●
Make sure that the environmental conditions comply with the protection class of the motor and
the electrical instruments.
●
Make sure that the installation space or location is vented such that sufficient cooling of the
machine is provided.
●
Make sure that cooling air inlets and outlets are not covered or obstructed and that the cooling
air flow is not affected adversely in any other way.
●
Make sure that the oil sight glass (OSG) remains easily visible.
●
Make sure that enough space remains for maintenance work.
●
Make sure that the machine is placed or mounted horizontally, a maximum of 1° in any direction
is acceptable.
●
26].
●
Make sure that all provided covers, guards, hoods, etc. are mounted.
If the machine is installed at an altitude greater than 1000 meters above sea level: