7 | Maintenance
26 | 40
Instruction Manual MINK MV 0500-0600 B_EN_en
Interval
Maintenance work
Monthly
●
Check the inlet screen, clean if necessary.
In case of an inlet filter (IF) being installed:
●
Check the inlet filter cartridge, replace if necessary.
Every 3 months
●
Check the oil level, see
Every 6 months
●
Clean the machine from dust and dirt.
In case of a coupling (CPL) being installed:
●
Check the coupling (CPL) for backlash and wear.
Every 20000 hours
●
Change the oil.
The change interval of 20000 operating hours is valid for
Busch approved oils only. The change interval depends very
much on the operating conditions. Borderline operation may
reduce the change interval down to approximately 5000
operating hours. Other oils may reduce the change interval.
Every 6 years
●
Have a major overhaul on the machine (contact Busch).
7.2
Oil Level Inspection
●
Shut down the machine.
●
When the machine is stopped, wait 1 minute before checking the oil level.
MAX
MIN
MAX
MIN
MAX
MIN
The oil level should stay constant over the lifetime of the oil. If the level does fall, this indicates a leak
and the machine requires repair.
●