Installation | 5
Instruction Manual MINK MV 0500-0600 B_EN_en
11 | 40
●
Contact your Busch representative, the motor should be derated or the ambient temperature
limited.
5.2
Connecting Lines / Pipes
WARNING
Rotating Parts.
Risk of severe injury!
●
Do not operate the machine without suction / discharge connection installed.
●
Remove all protective covers before installation.
●
Make sure that the connection lines cause no stress on the machine‘s connection; if necessary use
flexible joints.
●
Make sure that the line size of the connection lines over the entire length is at least as large as
the connections of the machine.
In case of long connection lines it is advisable to use larger line sizes in order to avoid a loss of
efficiency. Seek advice from your Busch representative.
5.2.1
Suction Connection
Connection size(s):
– G3
Depending on the specific order, other connection dimensions may apply.
5.2.2
Discharge Connection
Connection size(s):
– R2
Depending on the specific order, other connection dimensions may apply.
●
Make sure that the discharged gas will flow without obstruction. Do not shut off or throttle the
discharge line or use it as a pressurised air source.
●
Make sure that the discharge line either slopes away from the machine or provide a liquid
separator or a siphon with a drain cock, so that no liquids can flow back into the machine.
5.3
Filling Oil
NOTICE
Use of an inappropriate oil.
Risk of premature failure!
Loss of efficiency!
●
Only use an oil type which has previously been approved and recommended by Busch.
For oil type and oil capacity see
35].