6.1 Conveying Condensable Vapours
Use the machine in Aqua version for conveying water vapour or other condensable va-
pours. The machine in Aqua version is able to convey up to 100% saturated water va-
pour.
The conveyance of other vapours than water vapour shall be agreed upon with Busch.
• Make sure that any condensate from the suction side will not enter the non-operat-
ing machine.
• Before process:
• Warm up the machine by running the machine for 30 minutes.
• After process:
• During process condensate may occur in the machine. To remove the condens-
ate from the machine, convey dry air at 400 mbar with the machine’s maximum
speed for 30 minutes, after the process and at least once a day.
7
Maintenance
WARNING
Machines contaminated with hazardous material.
Risk of poisoning!
Risk of infection!
If the machine is contaminated with hazardous material:
• Wear appropriate personal protective equipment.
CAUTION
Hot surface.
Risk of burns!
• Prior to any action requiring touching the machine, let the machine cool down first.
NOTICE
Using inappropriate cleaners.
Risk of removing safety stickers and protective paint!
• Do not use incompatible solvents to clean the machine.
CAUTION
Failing to properly maintain the machine.
Risk of injuries!
Risk of premature failure and loss of efficiency!
• Respect the maintenance intervals or ask your Busch representative for service.
• Shut down the machine and lock against inadvertent start up.
• Vent the connected lines to atmospheric pressure.
If necessary:
• Disconnect all connections.