Parameter Overview | 7
0870166596_MV0040-0080C-D_PCI_A0004_IM_de_MD
19 / 56
Code Parameter
Min. Max. Unit Default ID
Description
P4.18 Stop mode activation
0
2
0
1895 0 = Normal
1 = quick stop
2 = accurate stop (from start signal 1)
Visibility of the group depends on P1.16
7.7 Digital Outputs: Menu PAR G5
Code Parameter
Min.
Max.
Unit Default ID
Description
P5.1
Relay output 1 content
0
14
2
313
0 = Not used
1 = Ready
2 = Run
3 = General fault
4 = General fault inverted
5 = Warning
6 = Reversed
7 = At speed
8 = Output frequency supervision
9 = Output current supervision
10 = Analogue input supervision
11 = Fieldbus 1
12 = Fieldbus 2
13 = External brake
P5.2
Relay output 2 content
0
14
3
314
See P5.1
P5.3
Digital Output 1 content
0
14
1
312
See P5.1
P5.4
Relay output 1 on delay
0
320
s
0
458
ON delay for relay
P5.5
Relay output 1 off delay
0
320
s
300
459
OFF delay for relay
P5.6
Relay output 1 inversion 0
1
0
1804 0 = no inversion
1 = inverted
P5.7
Relay output 2 on delay
0
320
s
0
460
See P5.4
P5.8
Relay output 2 off delay
0
320
s
0
461
See P5.5
Visibility of the group depends on P1.16