Maintenance | 7
Instruction Manual FOSSA FO 0015 A - FO 0035 B_EN_en
15 / 28
6.1.1 Gas Ballast Valve Adjustment
8 mm hex key
Open
Close
NOTE
Risk of back-flow when the gas ballast is open.
7
Maintenance
WARNING
Machines contaminated with hazardous material.
Risk of poisoning!
Risk of infection!
If the machine is contaminated with hazardous material:
• Wear appropriate personal protective equipment.
WARNING
Version intended for oxygen application.
Risk of fire!
• Do not perform maintenance task before being informed about oxygen requirements.
• Ask your Busch representative for more information.
CAUTION
Hot surface.
Risk of burns!
• Prior to any action requiring touching the machine, let the machine cool down first.
• Shut down the machine and lock against inadvertent start up.
• Vent the connected lines to atmospheric pressure.
If necessary:
• Disconnect all connections.