Installation | 5
Instruction Manual FOSSA FO 0015 A - FO 0035 B_EN_en
11 / 28
5.4 Electrical Connection
DANGER
Live wires.
Risk of electrical shock.
• Electrical installation work must only be executed by qualified personnel.
• Make sure that the power supply for the motor is compatible with the data on the
nameplate of the motor.
• Make sure that the motor of the machine will not be affected by electric or electro-
magnetic disturbance from the mains; if necessary seek advice from Busch.
• Connect the protective earth conductor.
Single-phase version:
• Electrically connect the machine directly to the mains connection (MC).
Connector: EN 60320-C14
On/off-switch (OOS):
O
►
OFF = Variable-frequency drive (VFD) not
powered
I
►
ON = Variable-frequency drive (VFD) powered
Fuse holder (FH): 12.5 A, type F (F12.5)
Three-phase version:
• Provide a lockable disconnect switch on the power line so that the machine is com-
pletely secured during maintenance tasks.
• Provide an overload protection according to EN 60204-1 for the motor.
• Electrically connect the machine, see