6 | Commissioning
14 / 28
Instruction Manual FOSSA FO 0015 A - FO 0035 B_EN_en
6
Commissioning
WARNING
FO 0035 B operates at 100 hPa (mbar) in continuous operation.
Risk of damage to the machine!
ATEX
►
Risk of explosion and injuries!
• Make sure to comply with the maximum continuous suction pressure, see
.
CAUTION
During operation the surface of the machine may reach temperatures of more than
70°C.
Risk of burns!
• Avoid contact with the machine during and directly after operation.
NOTE
A small amount of tip seal dust may collect in the exhaust duct of the machine. The dust
may be blown out when the machine is vented.
• Make sure that the installation conditions (see
) are met.
• Switch on the machine.
• Make sure that the maximum permissible number of starts does not exceed 6 starts
per hour. Those starts should be spread within the hour.
NOTE
For the single phase version, take into account a delay of 5 seconds between power-up
and the machine start up.
• Make sure that the operating conditions comply with the
.
As soon as the machine is operated under normal operating conditions:
• Measure the motor current and record it as reference for future maintenance and
troubleshooting work.
6.1 Conveying Condensable Vapours
30 minutes
* not included in the scope of delivery
• Close the isolation
valve* and
open the gas ballast
valve** (GB)
• Warm up the machine
• Open the isolation
valve and perform the
process
• Close the isolation
valve
END
START
30 minutes
• Close the gas ballast
valve
** may be considered as optional on certain products