5 | Installation
14 | 48
Instruction Manual COBRA NC 0100-0300 B ACV_EN_en
●
Connect the barrier gas connection (BGC) to the gas supply.
Connection size:
– G1/4, ISO 228-1
●
Electrically connect the flow switch (FS) of the flow meter, see Wiring Diagram Flow Switch [
If a pressure switch is installed:
●
Electrically connect the pressure switch, see Wiring Diagram Pressure Switch (Optional) [
25].
●
Make sure that the gas complies with the following requirements:
Gas type
Dry nitrogen or air
Gas temperature
°C
0 ... 60
Maximum gas pressure
bar
13
Recommended pressure setting at the pres-
sure regulating valve (PRV)
bar(a)
3
Filtration
µm
5
Recommended flow rate
for labyrinth seals, oil lubricated single me-
chanical seals and PTFE shaft seals
SLM (standard li-
ter per minute)
2.5 ... 3
Recommended flow rate
for gas lubricated double mechanical seals
SLM (standard li-
ter per minute)
≤
1
Air quality (only for air)
Acc. to ISO
8573-1
Class 5.4.4.
5.2.4
Dilution Gas System Connection (Optional)
PRV
DGC
MAN
FME, FR
NIP
Description
DGC
Dilution gas connection
FME
Flow meter
FR
Flow regulator
MAN
Manometer
NIP
Nitrogen panel
PRV
Pressure regulating valve