background image

1473-1-8108  

  Rev. 01  

  20.09.2012 

Operating Instructions 

Busch-Wächter

®

 

 

 

Pos: 2 /#Neustruktur#/Online-Dokumentation (+KNX)/Titelblätter/Waechter/Titelblatt - 6842 - IR-Servicehandsender @ 25\mod_1340349812156_15.docx @ 219804 @  @ 1 

 

 
6842-101 
IR service remote control 
 

 
 

 

 

 

 

 

 
 

 

=== Ende der Liste für Textmarke Cover === 

 

Summary of Contents for 6842-101

Page 1: ...ng Instructions Busch Wächter Pos 2 Neustruktur Online Dokumentation KNX Titelblätter Waechter Titelblatt 6842 IR Servicehandsender 25 mod_1340349812156_15 docx 219804 1 6842 101 IR service remote control Ende der Liste für Textmarke Cover ...

Page 2: ...1 Intended use 3 2 Environment 3 3 Setup and function 4 3 1 Features of function and equipment 4 3 2 Possible combinations 5 4 Operation 6 4 1 Display area 7 4 2 Service area 8 4 3 Navigation area 8 4 4 Function area 9 5 Technical data 10 6 Commissioning 11 6 1 Removing the protective foil 11 6 2 Programming the device 11 7 Maintenance 11 7 1 Battery change of remote control 11 Ende der Liste für ...

Page 3: ...ic devices must not be disposed of with domestic waste The device contains valuable raw materials which can be recycled Therefore dispose of the device at the appropriate collecting depot Do not dispose of the batteries with domestic waste Take the used batteries to the collecting depot for recycling Many retailers have collection boxes for used batteries Pos 8 3 Neustruktur Online Dokumentation K...

Page 4: ...ntrol 6841 101 can only be operated with Bush Watchdogs 110 MasterLINE and 220 280 MasterLINE Pos 12 Neustruktur Online Dokumentation KNX Überschriften Für alle Dokumente 2 Ebene A F Funktions und Ausstattungsmerkmale 23 mod_1336557630140_15 docx 209136 222 1 3 1 Features of function and equipment Pos 13 Neustruktur Online Dokumentation KNX Aufbau und Funktion Waechter Ausstattungsmerkmale 6842 10...

Page 5: ... docx 109520 22 1 3 2 Possible combinations Pos 16 Neustruktur Online Dokumentation KNX Kombinationsmöglichkeiten Waechter Kombinationsmöglichkeiten 6842 101 IR Servicehandsender 28 mod_1347364537152_15 docx 232736 11 1 6842 101 6855 110 MasterLINE X 6847 6867 220 280 MasterLINE X Pos 17 Neustruktur Online Dokumentation KNX Steuermodule Online Dokumentation Für alle Dokumente Seitenumbruch 9 mod_1...

Page 6: ...ontrol is divided into four areas No Function 1 Display area In this are the currently set functions of the Busch Watchdog unit are displayed 2 Service area In this area the selected functions are transmitted In this area the settings of the IR service remote control are requested 3 Navigation area In this area the functions are selected In this area the set values are transmitted 4 Function area ...

Page 7: ...during twilight 15 20 lux Daytime operation 350 lux 3 In this area the sensitivity of the movement detector is set A reduced sensitivity is necessary in a disturbed environment trees bushes in the detection range or excessively long ranges 4 In this area additional functions are switched on and off Dynamic forced switch off Only for 220 MasterLINE premium Separation of detection zones 1 and 2 Sync...

Page 8: ... 1 second 2 Displays the current settings of the IR service remote control via the LED matrix 3 Activate the test mode Activation test for 10 minutes or deactivate it 4 3 Navigation area Fig 3 Navigation area No Function 1 Brief press of the button Activate the display area Select the functions 2 Long press of the button at least 1 second Send the settings of the IR service remote control to the B...

Page 9: ...presence simulation 4 Activation of presence simulation Continuous light between twilight and 22 30 p m CET or 23 30 CEST Followed by movement detection 5 Light deactivation for 4 hours no detection of movement 6 Light activation for 4 hours no detection of movement 7 Deactivating automatic movement detection and 4 hours light On Off Pos 20 Neustruktur Online Dokumentation KNX Steuermodule Online ...

Page 10: ...chter Technische Daten 6842 101 IR Servicehandsender 25 mod_1340604622237_15 docx 219913 1 1 Designation Value Operating voltage 3 V DC Battery type CR 2025 Battery life Approximately 2 years Horizontal detection coverage Busch Watchdog 220 280 MasterLINE Maximum of 6 m Busch Watchdog 110 MasterLINE Maximum of 2 m Operating temperature 0 C 45 C Protection type IP 40 Pos 23 Neustruktur Online Dokum...

Page 11: ...ctivating the power on the Busch Watchdog The Busch Watchdog must be de energized for at least 30 seconds The remote control will then automatically connect itself to the Busch Watchdog and the Busch Watchdog will flash if the reception is correct Repeat these steps to program a maximum of 9 additional remote controls Pos 26 Neustruktur Online Dokumentation KNX Überschriften Für alle Dokumente 1 E...

Page 12: ... Notice We reserve the right to at all times make technical changes as well as changes to the contents of this document without prior notice The detailed specifications agreed to at the time of ordering apply to all orders ABB accepts no responsibility for possible errors or incompleteness in this document We reserve all rights to this document and the topics and illustrations contained therein Th...

Reviews: