Technical data
PROFIBUS manual
Version FELD-V2002.02
Page 7
2 Technical
data
PROFIBUS DP system data
Number of devices or modules 126 with repeaters
Transmission medium
Cu cable to EN 50 170
Max. bus segment length
100 m to 1200 m (dependent on baud
rate/cable)
Data transfer rates
9.6 kbaud to 12 Mbaud (dependent on
cable)
Type 9310 device data
Supported transfer rates
9.6 kbit/s
187.5 kbit/s
3000 kbit/s
19.2 kbit/s
500 kbit/s
6000 kbit/s
93.75 kbit/s
1500 kbit/s 12,000 kbit/s
Bus connector
9 pin SUB-D socket (female)
ID
number
06E5
Hex
GSD
file
BUR_06E5.gsd
Address range
0 to 126
Electrical
safety
Reverse voltage protection
Yes
Air clearance/leakage paths
To DIN EN 61131-2 and DIN EN 50178
Overvoltage category II,
Pollution degree 2
Electrical
isolation
Between
fieldbus and internal electronics
Withstand voltage
DC 500 V
Electromagnetic compatibility
(see also the operating manual for DIGIFORCE
®
type 9310)
Interference immunity to EN50082-2 : 1995
EN 61000-4-2
4 kV/8 kV
(2/4)
B
EN 61000-4-3
10 V/m 80 % AM
(3)
A
EN 61000-4-4
2 kV
(3/4)
A
EN 61000-4-6
10 V/m 80 % AM
(3)
A
Emitted interference to EN50081-2 : 1994
EN 55011
30 dBµV/m
(30 m)
37 dBµV/m
Notes on CE labeling
burster
equipment carrying the CE mark meets the requirements of the EU
directives and the harmonized European standards (EN) cited therein.
The EU declarations of conformity are available to the relevant authorities as
specified in the directives. A copy of the declaration of conformity is
included in the relevant equipment documentation.