
PROFIBUS DP data protocol
Page 18
Version FELD-V2002.02
PROFIBUS manual
5.4 Message structure / data break-down
5.4.1 Minimum general curve data:
Min. Y of whole curve (X-coordinate)
Min. Y of whole curve (Y-coordinate)
Max. Y of whole curve (X-coordinate)
Max. Y of whole curve (Y-coordinate)
Last curve value (X-coordinate)
Last curve value (X-coordinate)
4-byte float number (see appendix A)
4-byte float number ( “ )
4-byte float number ( “ )
4-byte float number ( “ )
4-byte float number ( “ )
4-byte float number ( “ )
5.4.2 Full general curve data:
Min. X of whole curve (X-coordinate)
Min. X of whole curve (Y-coordinate)
Max. X of whole curve (X-coordinate)
Max. X of whole curve (Y-coordinate)
Min. Y of whole curve (X-coordinate)
Min. Y of whole curve (Y-coordinate)
Max. Y of whole curve (X-coordinate)
Max. Y of whole curve (Y-coordinate)
First curve value (X-coordinate)
First curve value (Y-coordinate)
Last curve value (X-coordinate)
Last curve value (X-coordinate)
4-byte float number (see appendix A)
4-byte float number ( “ )
4-byte float number ( “ )
4-byte float number ( “ )
4-byte float number ( “ )
4-byte float number ( “ )
4-byte float number ( “ )
4-byte float number ( “ )
4-byte float number ( “ )
4-byte float number ( “ )
4-byte float number ( “ )
4-byte float number ( “ )
5.4.3 Entry/Exit:
For pass-through window, online window:
Window entry (X-coordinate)
Window entry (Y-coordinate)
Window exit (X-coordinate)
Window exit (Y-coordinate)
4-byte float number (see appendix A)
4-byte float number ( “ )
4-byte float number ( “ )
4-byte float number ( “ )
For block window
Window entry (X-coordinate)
Window entry (Y-coordinate)
Block value (X-coordinate)
Block value (Y-coordinate)
4-byte float number (see appendix A)
4-byte float number ( “ )
4-byte float number ( “ )
4-byte float number ( “ )