27
Installing Damper and Chimney System
Dampers may not be required on Outdoor Fireplaces, consult
with your local Building Department. Refer to Page 14 of this
manual for speci c approved chimney requirements before
proceeding.
All chimney systems
(Sold Separately by Burntech®)
must
be installed with an integrated Damper System / Anchor Plate
installed on or in the replace. Installers are cautioned to put
the chimney system together exactly as instructed and shown
in chimney manufacturer’s guide. Any modi cations may have
serious consequences resulting in an accident or malfunction.
If instructions are not followed, the warranty on the product will
become null and void.
Top Mounted Damper System / Anchor Plate:
1. Apply a 1/4” bead of gasket cement around the base of
the Anchor Plate as shown in
Figure 54
. Apply a 1” thick
ceramic ber blanket to the gasket cement.
Figure 54
Apply a 1/4” bead of
gasket cement around
base of Anchor Plate
2. Apply balance of gasket cement in a 1/4” bead on top of
smoke dome approx. 1-1/2” around periphery of chimney
hole. Install damper assembly on top of unit pressing
damper and insulation blanket into cement. Secure with
four 1/4” X 1-14” masonry fastener.
Figure 55
Adhere 1” ceramic ber
blanket under Anchor Plate.
Secure with four 1/4” x
1-1/4” masonry fastener.
1/4” bead of
gasket cement
3. Place chimney adapter onto top of damper plate and center
in opening using gasket supplied with adapter.
4. Attach adapter with screws supplied by carefully drilling
holes into damper plate.
5. Attach damper chain stop on center rear of lintel 3” vertical
from opening using (3) #8 cement fasteners.
Traditional Steel Damper Option:
Requires a Burntech® Steel Damper and Damper Blocks
(Sold Separately. Refer to the products list at the back of your
Manual for the properly sized Damper and Damper Blocks for
your speci c model)
1.
Install properly sized Burntech® Damper Blocks as shown
in Figure 56.
2. Install a properly sized Burntech® Damper Plate (sold
separately) per manufacturer’s instructions.
3.
Pre-drill Damper with 1/4” steel bit at the locations shown
in Figure 56.
g
Figure 56
Optional Burntech®
Damper Blocks
Optional Burntech®
Damper
4. Pre-drill Damper blocks with 3/16” masonry drill bit. Drill
the hole 1 1/4 Inches deep.
5. Install (5) 1/4 inch by 1 1/4 inch long masonry screws (sold
separately). LIGHTLY TIGHTEN SCREWS UNTIL THEY
ARE SNUG. OVER TIGHTENING WILL RESULT IN A
BROKEN DAMPER BLOCK
Attention:
Clearance to combustible construction cannot be
reduced during course of construction. For the safe operation
of the nished replace, these clearances must be followed
when building the framework for the chimney system.
Note that the most important aspect of the installation is
maintaining the minimum required clearances to combustible
materials according to the chimney pipe manufacturer’s
recommendations, otherwise a potential re hazard may occur.
Warning:
do not interchange chimney manufacturer’s parts
with any other parts except those speci cally required by
the chimney manufacturer’s recommendations otherwise a
potential hazardous condition may be created.
Attention:
When choosing a Chimney System it must meet
the following requirements:
Designed for installation in accordance with the National Fire
Protection Standard and UL 103.
Meets the requirements of NFPA 211.
Designed in accordance with ICC Codes.
Optional:
Assuming you have sections of vertical pipe that are more than
10’ (ten feet) measuring between elbows, you must insert – at
midpoint – a chimney stabilizer. When installing the stabilizer,
pull out the support straps with a good amount of tension and
hammer to the frame.
Please
refer to the approved chimney pipe manufacturers’
installation instructions.
Figure 57
Return
Elbow
Elbow
Return
Elbow
Elbow
6' Max.
6' Max.
A
6' Max.
6' Max.
Return
Elbow
Elbow
Elbow
Return
Elbow
B
6' Max.
6' Max.
C
Elbow
Return
Elbow
Ceiling Support
Pipe 16S-16DM
Summary of Contents for OFS-33
Page 2: ...This page has been left intentionally blank ...
Page 39: ......