38
107672-03 - 5/18
Option #
37
38
39
Illustrated in Figure
7.23, 7.24
7.23, 7.24
7.25a
Pipe Penetration
Through Structure
Vent
Roof
Roof
Roof
Intake
Wall
Wall
Wall
Material
Vent
Centrotherm
InnoFlue (Rigid/Flex)
Centrotherm
InnoFlue (Rigid/
Flex)
DuraVent
FasNSeal
Flex
Intake
PVC
PVC
PVC
Nominal Diameter
Vent
2”
3”
3”
Intake
2” or 3”
3”
3”
Min Equivalent Vent Length:
Models
080
48”
48”
48”
100
48”
48”
48”
120
Not Permitted
48”
48”
150
52”
52”
180
52”
52”
Max Equivalent Vent Length (Note 1):
Models
080
60ft
135ft
135ft
100
60ft
135ft
135ft
120
Not Permitted
135ft
135ft
150
135ft
135ft
180
135ft
135ft
Rigid Vent Terminals
Vent
Not Permitted
Intake
Flex Termination
& Components
(Masonry Chimney
Chase) (Note 3)
Vent
IFCK02**
IFCK03**
3FSFLEX-**
FSFLEXRC3
Intake
90 Elbow
w/Screen
90 Elbow
w/Screen
90 Elbow
w/Screen
Flex Termination &
Components (B-Vent
Chimney Chase)
Vent
IFBK02****
IFBK03****
Not
Permitted
Intake
90 Elbow
w/Screen
90 Elbow
w/Screen
* Specify size of B vent (e.g. 2PPS-BV
6
is for use with 6” B vent).
** Specify length in feet.
**** Specify Flex length and B vent diameter (e.g. IFBK02
2505
includes 25ft of flex and used with 5” B vent).
Note 1: Max vent lengths shown also apply to the intake. Flex vent reduces the maximum allowable vent length in some
applications. See equivalent lengths for flex vent shown in Table 7.14 and sizing example on page 35.
Note 2: First 30” plus first exhaust elbow are CPVC.
Note 3: See vent manufacturer’s installation manual for gaskets, spacers and other required vent components.
All vertical terminals require compatible roof flashing and storm collars.
VII. Venting
D. Design Requirements Unique to Split Vent Systems (continued)
Table 7.21: Summary of Split Vent System Options (cont.)
Summary of Contents for K2WT Residential
Page 88: ...88 107672 03 5 18 X Wiring continued Figure 10 7 Internal Ladder Diagram ...
Page 89: ...89 107672 03 5 18 PAGE LEFT INTENTIONALLY BLANK ...
Page 90: ...90 107672 03 5 18 X Wiring continued ...
Page 91: ...91 107672 03 5 18 Figure 10 8 Internal Wiring Connections Diagram X Wiring continued ...
Page 103: ...103 107672 03 5 18 Lighting and Operating Instructions XI Start Up and Checkout continued ...
Page 148: ...148 107672 03 5 18 XV Service Parts continued ...
Page 152: ...152 107672 03 5 18 XV Service Parts continued ...
Page 154: ...154 107672 03 5 18 XV Service Parts continued 85 86 91 95 ...
Page 163: ...163 107672 03 5 18 ...
Page 164: ...164 107672 03 5 18 ...
Page 165: ...165 107672 03 5 18 ...
Page 166: ...166 107672 03 5 18 ...
Page 167: ...167 107672 03 5 18 ...