![Burnham 5006B Installation And Operation Manual Download Page 43](http://html1.mh-extra.com/html/burnham/5006b/5006b_installation-and-operation-manual_2832904043.webp)
43
3.
CONDENSATION
Following a cold start, condensation (sweating) may
occur in a gas fired boiler to such an extent that it
cONTROL VARiATiONS
NATURAL GAS
MODeL NO.
cONTROL
SYSTeM
TYPe OF
PiLOT
GAS VALVeS
OPTiONAL MAiN
VALVeS
ReFeReNce
PAGe
PiLOT
MAiN
5006B-5009B (USA)
EI
Elec. Ign.
(1) 7000DERHC-S7C
(B)
45
5010B-5026B (USA)
5006B-5026B (CANADA)
EI
Elec. Ign.
(1) H91WG-6
(2) V88A
(B)**
46-48
5006B-5026B
(USA & CANADA)
OP
Standing Q179D
(1) L62GB-3C
(2) V88A
(A), (B)
51 & 53
5008B-5026B
(USA & CANADA)
EP
Elec. Ign. Q179C
(1) H91WA-4
(2) V88A
(A), (B)*
55 & 56
5006B-5013B (CANADA)
24V
Standing
(1) L62GB-3C
(2) V88A
(A), (B)
59
5015B-5024B (CANADA)
24V
Standing
(1) 62GB-3C
(2) V88A
(A), (B)
60
LP GAS
MODeL NO.
cONTROL
SYSTeM
TYPe OF
PiLOT
GAS VALVeS
OPTiONAL MAiN
VALVeS
ReFeReNce
PAGe
PiLOT
MAiN
5006B-5009B (USA)
EI
Elec. Ign.
(1) 7000DERHC-S7C
45
5006B-5026B (USA)
OP
Standing Q179D
(1) L62GB-3C
(2) V88A
(A)
51 & 53
5006B-5026B (CANADA)
OP
Standing Q179D
(1) L62GB-3C
(2) V88A
---
51 & 53
(A) -- (1) Honeywell V5055B Motorized Gas Valve with V4055A/V4062A/V9055A Actuator and (1) ITT K3A
Solenoid Valve (120V)
(B) -- (1) Honeywell V8944B Combination Gas Valve and (1) ITT K3A Solenoid Valve (24V)
* -- To be used with (1) H91WA-4 Pilot Valve (120V)
** -- To be used with (1) H91WG-6 Pilot Valve (24V)
NOTE:
1. For Steam or Water
2. For 24V Thermostat Application - Wire S861OM Relay in Place of Operating Control Set Thermostat Heat
Anticipator at 0.4 Amp. See Pages 45, 46 and 47.
3. All Battery Operated Thermostats
must
be Electrically Isolated From the Primary Circuit by an Isolating Relay.
appears that the boiler is leaking. This condensation
can be expected to stop after the boiler is hot.
SecTiON iV - OPeRATiON (continued)
Summary of Contents for 5006B
Page 10: ...10 Fig 6 ARRANGEMENT OF SECTIONS AND CANOPY S SECTION III INSTALLATION INSTRUCTIONS continued...
Page 22: ...22 Fig 22 SECURING OF CANOPY DRAFTHOOD SECTION III INSTALLATION INSTRUCTIONS continued...
Page 23: ...23 Fig 23 CANOPY DRAFTHOOD MOUNTING DIAGRAM SECTION III INSTALLATION INSTRUCTIONS continued...
Page 68: ...68 Fig 58 PILOT LOCATIONS SECTION V SERVICE continued...
Page 72: ...72 SERVICE RECORD DATE SERVICE PERFORMED...
Page 74: ...74 Fig 64 BASE PARTS 5006B Thru 5014B SECTION VI REPAIR PARTS continued...
Page 76: ...76 Fig 65 BASE PARTS 5015B thru 5026B SECTION VI REPAIR PARTS continued...
Page 78: ...78 Fig 66 INTEGRAL CANOPY DRAFTHOODS SECTIONS SECTION VI REPAIR PARTS continued...
Page 82: ...82 Fig 67 JACKETS SECTION VI REPAIR PARTS continued...
Page 111: ...111 SERVICE RECORD DATE SERVICE PERFORMED...
Page 112: ...112...