background image

 

- 20 - 

4.

 

Burley Appliances Ltd - Domestic Guarantee Conditions? 

We pride ourselves on the quality of service we deliver to our customers and all Burley Appliances’ 
products carry a fully inclusive 12-month parts and labour guarantee. This guarantee is extended 
by another 12 months free of charge provided that your appliance is registered with us within two 
weeks of installation and that it is serviced by Gas Safe ™ registered installer (formerly CORGI) at 
the  end  of  the  first  year.  What  the  guarantee  cannot  cover  is  problems  caused  by  incorrect 
installation or servicing, or any work carried out by a non- Gas Safe ™ registered installer (formerly 
CORGI). 
 

We undertake that if within 12 months of the date of purchase, your fire or any part thereof is proved to be 
defective by reason of faulty workmanship or materials, we will at our discretion repair or replace the same 
free of any charge for labour, materials or carriage subject to condition that: 
 

 

All gas appliances are installed to the latest Gas Installation regulations by a qualified Gas 

Safe  ™  registered  installer  (formerly  CORGI)  and  connected  to  the  correct  gas  type  and 
pressure as stated on the rating plate attached to the equipment. 

 

The fire is fitted in a room with the following minimum dimensions 2.5Kw = 30m

3

 / 3.5Kw = 

40m

3

 / 4.2Kw = 50m

3

 

 

A wall vent is installed not less than 1 meter away from the fire allowing 100cm

2

 of free air. 

 

You have the fire serviced by a Gas Safe ™ registered installer (formerly CORGI) within the 

first year (as with all gas products, every gas appliances must be serviced every year). 

 

The  appliance  has  not  been  subject  to  misuse,  accident,  or  repaired  or  fitted  by  anyone 

other than a Gas Safe ™ registered installer (formerly CORGI) or our own engineer. 

 

The appliance has been used solely for domestic purposes and is on domestic premises i.e. 

not for commercial or trade use. 

 

The appliance has been used solely in accordance with the instruction book. 

Any in guarantee work carried out by Burley Appliances will be charged for if the fault is caused by 

incorrect pressure or gas, incorrect installation, operator error, neglect or abuse. 

All  guarantee  cover  is  instantly  and  permanently  cancelled  if  a  non-  Gas  Safe  ™  registered 
installer (formerly CORGI) carries out any installation or servicing.

 

Exclusions 

This guarantee 

does not

 cover: 

 

Damage resulting from external transportation, improper use or neglect, the replacement 
of any light bulbs or removable parts of glass or plastic. 

 

Costs incurred for calls to put right an appliance, which is improperly installed. 

 

Appliances that are the subject of rental agreements. 

 

EC  Countries  -  the  standard  guarantee  is  applicable  but  is  subject  to  the  owner's 
responsibility and cost, to ensure the appliance meets the standards set by the country to 
which the product is taken.  

Any appliance or defective part replaced shall become the Company's property 

Service Calls are made between 09.30 am and 04.30 pm Monday - Friday.  

This guarantee is in addition to your statutory and other legal rights. 

Proof of purchase will be required as will be a copy of the Gas Safe™ registered (formerly CORGI) 
installer notice. 

 
© Burley Appliances Ltd 2009

 

Summary of Contents for G4237 IMAGE

Page 1: ...Ltd Lands End Way Oakham Rutland LE15 6RB Telephone 44 0 1572 756956 Fax 44 0 1572 724390 e mail info burley co uk web www burley co uk G4237 8InstUser G20 31 Issue March09 v 3 TO OBTAIN YOUR FIRST YE...

Page 2: ...lbow 85 The inlet pressure must be within 1mBar of specification with all gas appliances in the house switched on and also with just the Burley heater operating If outside of this tolerance the fault...

Page 3: ...lled in high rise blocks of flats bed sitting rooms basements which are not open on at least one side bathrooms or bedrooms in corridors stairways landing or hallways of multi occupancy dwellings gara...

Page 4: ...the top surface standing a minimum of 50mm above surrounding floor level or surrounded by a raised fixed fender of 50mm high The hearth must extend a minimum of 100mm in front of the fire bed and 50m...

Page 5: ...s are of the correct type Use all 6 screw holes in the brackets to attach to the wall If the appliance is hearth mounted the fixing is intended to prevent the appliance from moving toppling and it is...

Page 6: ...they have a minimum heat rating of 150o c Consideration should be given to the effect of expansion and contraction caused by temperature and back panels should be allowed to float or attached with a...

Page 7: ...erature The case can be test fitted to the chassis to ensure clearance The gap in the case top between grille and spacer slides over the top flange on the appliance The bottom of the case has folded o...

Page 8: ...ry pack and also explain that the batteries are not covered by warranty A handheld remote control is included in the box and this has a 9 volt battery to power it The battery should be changed annuall...

Page 9: ...the main burner will not light check the thermostat position and if necessary select a warmer setting 9 2 To light the fire first ensure the red knob is turned clockwise to OFF Press the left hand red...

Page 10: ...tally friendly manner Replacement rechargeable batteries for the fire and replacement handsets are available from Burley Appliances on 01572 756956 or through your retailer The 9 volt handset battery...

Page 11: ...ormance and could lead to a hazard 10 4 FIREFRONTS The design of these affects combustion therefore only the correct front supplied with the appliance may be fitted 10 5 FIREGUARDS A fireguard is not...

Page 12: ...t to the gas supply Test all joints for leaks Following the manufacturer s instructions re lay the fuel bed and replace the glass Light the fire using the method in the instructions and ensure that th...

Page 13: ...athrooms bedrooms in corridors stairways landings or hallways of multi occupancy dwellings in garages or rooms containing petroleum products The guard on the appliance is to prevent risk of fire or in...

Page 14: ...eater in which case they will select a flame height on the red knob then set the thermostat black knob to a comfort level In both cases if the room gets too hot the thermostat will automatically reduc...

Page 15: ...about 20 seconds and then it will light the burner on high flame 6 To alternate between high and low flame use the flame buttons on the right hand side of the handset 7 To turn the fire OFF press the...

Page 16: ...appliances to produce an initial odour after start up If the pilot flame should ever extinguish of its own accord ventilate the room and allow a minimum of 5 minutes before relighting Never attempt t...

Page 17: ...67 and the test must be carried out in accordance with BS5871 Pt 4 The catalytic converter needs heat to work therefore before you start testing the fire must have been lit and burning on full for at...

Page 18: ...sult the relevant manufacturer Only use replacement catalyst supplied by Burley If you or the customer detects any odours from the fire please remember that the catalytic convertor is not an air filte...

Page 19: ...is important to take a gas rate test over a reasonable period of time so that the capacity of the meter is used On low Input appliances such as our flueless this is even more critical because uncertai...

Page 20: ...the first year as with all gas products every gas appliances must be serviced every year The appliance has not been subject to misuse accident or repaired or fitted by anyone other than a Gas Safe re...