General safety requirements

`

`

Read these directions for use carefully before using.

`

`

Keep these directions for use where they will be 
accessible for all users.

`

`

Failure to comply with the directions for use shall 
render all warranty conditions null and void and 
may lead to personal injury and material damage.

`

`

The instrument must only be used by qualified 
skilled employees.

Safety instructions before using

`

`

Follow the manufacturer‘s instructions and safety 
instructions of the medium you are filling.

`

`

Damage to the respiratory tract and other organs 
due to off-gassing media. Fill only in ventilated 
rooms or under a suitable exhaust hood.

`

`

The instrument must only be used within the 
confines of applicable material resistance and for its 
designated purpose. Any other type of use will affect 
the warranty/guarantee.

Safety instructions during and after use

`

`

The instrument generates overpressure. Possible 
bodily injury due to escaping liquids.

`

`

The instrument is not suitable for cleaning in a 
dishwasher.

Layout and function

`

`

The instrument consists of a riser pipe made of 
polypropylene (PP), a discharge tube made of PVC 
with a tip made of silicone, a shut-off valve made of 
PP and PE and a universal bung made of PVC.

`

`

The instrument is suitable for a safe filling of car 
batteries with acid or distillated water.

`

`

The bung fits onto container openings with a diame-
ter of 30 to 70 mm forming an airtight seal.

`

`

The instrument is maintenance-free.

Point out any damage in the packaging to the freight 
forwarder/supplier immediately.

Assembly

1. Pull out the telescopic riser pipe 

 completely.

2. Guide the riser pipe 

 with the universal bung 

 

into the container to form an airtight seal.

3. If necessary adjust the universal bung to the 

opening diameter of the container.

4. Close the shut-off valve 

 on the discharge hose.

5. Plug the hand pump ball 

 into the bung.

6. Close the stop-valve 

 (push the lever upwards).

Safe filling

1. Hold the discharge hose in the filling container.
2. Activate the hand pump ball and generate overpres-

sure. Liquid starts to flow.

3. Open the shut-off valve on the discharge hose.

 WARNING!

The instrument is not suitable for highly flammable 
or explosive liquids.

`

`

The instrument must only be used within the 
confines of applicable material resistance and 
for its designated purpose.

NOTE!

Before using, the instrument has to be cleaned to 
the extent of your (validated) cleaning process.

`

`

Measures of manual cleaning have to be carried 
out in the cleaning/desinfection area and under 
consideration of occupational health and safety.

`

`

Pay attention to the material resistance.

 

Ø 30 - 50 mm

 

Ø 40 - 60 mm

 

Ø 50 - 70 mm

 WARNING!

Some liquid will continue to run while the dischar-
ge hose is being screwed on. Bodily injury due to 
escaping liquid.

`

`

Close the shut-off valve on the discharge hose 
before mounting.

Summary of Contents for OTAL

Page 1: ...Pumpen Probenehmer Laborbedarf f r Labor Industrie und Wissenschaft Pumps Sampling Plastic Labware for Laboratory Industry Science Gebrauchsanleitung Directions for use Instrucciones para el uso Instr...

Page 2: ...der destilliertem Wasser geeignet Der Stopfen kann auf Gebindedurchmesser von 30 70 mm Durchmesser dichtschlie end aufgesetzt werden Das Ger t ist wartungsfrei Sch den an der Verpackung umgehend beim...

Page 3: ...bei Abziehen des Auslauf schlauches K rperverletzung durch austretende Fl ssigkeit Absperrhahn an Auslaufschlauch schlie en Auslaufschlauch anheben und Fl ssigkeit in Gebinde zur cklaufen lassen 4 Zu...

Page 4: ...distillated water The bung fits onto container openings with a diame ter of 30 to 70 mm forming an airtight seal The instrument is maintenance free Point out any damage in the packaging to the freigh...

Page 5: ...op valve is not suitable for precise dosing CAUTION The container is under pressure Bodily injury due to escaping liquid Slowly remove the instrument from the container WARNING Some liquid will contin...

Page 6: ...re de PP y PE y un tap n universal de PVC El aparato es apropiado para un trasvase seguro de baterias de coches con cido o agua destilada El tap n se adapta a aberturas de recipientes con un di metro...

Page 7: ...el aparato del recipiente 3 Lave el aparato con una soluci n l quida con pH neutro NOTA La v lvula de cierre no es adecuada para la dosifi caci n precisa PRECAUCI N El recipiente est presurizado Ries...

Page 8: ...robinet d arr t en PP et PE et un bouchon universel en PVC L appareil est appropri pour le remplissage s r de bat teries automobiles avec de l acide ou de l eau distill e Le bouchon s adapte tanche l...

Page 9: ...ever l appareil avec pr caution du r cipient 3 Rincer l appareil avec un liquide au pH neutre REMARQUE La valve d arr t n est pas appropri e pour doser pr cis ment ATTENTION R cipient sous pression en...

Page 10: ...30 70 1 2 3 4 5 6 30 50 mm 40 60 mm 50 70 mm...

Page 11: ...1 2 3 4 5 6 1 2 3 pH 1 2 1 2...

Page 12: ...Bouchon universel Auslaufschlauch Discharge hose Tubo de descarga Flexible de sortie Handpumpenball Hand pump ball Bola accionamien to manual Balle de pompe Stopventil Stop valve V lvula de cierre Va...

Reviews: