20 - 0911
english
DOWNLOAD (HOT-KEY
CONTROL DEVICE)
Switch off the POWER SUPPLY to the controller, or set it to STAND-BY.
Insert the HOT-KEY up to the stop in the marked position on the controller.
Re-activate the controller.
The default parameters of the HOT-KEY will be automatically written into the
controller. During this time, the DoL message blinks in the display. The
programming prpcedure is finished after 10 sec, and normal operation
starts automatically with the new parameter set.
The HOT-KEY can be removed.
5
HOT-KEY function
Writing the stored parameter set from the HOT-KEY into the control device:
end for a correct data transfer
err for a failed data transfer
In this case, switch off the power to the device in order to repeat the
procedure. If you want to cancel the procedure, simply remove the HOT-
KEY.
The following messages are possible at the end of the data transfer:
UPLOAD (CONTROL DEVICE
HOT-KEY)
Insert the HOT-KEY into the provided position when the controller is
switched on again.
Operate 1x with
. The message uPL is displayed.
Press the SET button in order to start the data transfer. uPL starts to blink.
You can remove the HOT-KEY again after about 10 seconds.
Writing the current default parameters of the control device into the HOT-KEY:
end for a correct data transfer
err for a failed data transfer
In this case, press the SET button again to repeat the procedure. If you
want to cancel the procedure, remove the HOT-KEY.
The following messages are possible at the end of the data transfer: