Burkert PTB 01 ATEX 2175 Operating Instructions Manual Download Page 7

7

General information

to avoid the risk of explosion, the following must be observed 

for operation in explosion-risk areas:

 

Information on the temperature class, ambient temperature, 

degree of protection and voltage on the type label for explosion-

risk areas.

 

Installation, operation and maintenance may only be performed 

by qualified specialists. 

 

The  applicable  safety  regulations  (including  national  regula-

tions) as well as general technical standards must be observed 

during setup and operation. 

 

Repairs may only be performed by the manufacturer.

 

The device must not be exposed to any mechanical and/or 

thermal loads which exceed the limits specified in the operat-

ing instructions.

general hazardous situations.

To prevent injury, ensure:

 

Secure system/equipment against unintentional activation.

 

Observe the direction of flow during installation.

 

After an interruption in the power supply or pneumatic supply, 

ensure that the process is restarted in a defined or controlled 

manner.

 

Don’t use the device as a lever when screwing the valve into 

the line.

Failure to observe this operating manual and its operating 

instructions  as  well  as  unauthorized  tampering  with  the 

device release us from any liability and also invalidate the 

warranty covering the devices and accessories!

general infOrmatiOn

4.1 

Contact addresses

germany

Bürkert Fluid Control Systems

 

Sales Center

 

Christian-Bürkert-Str. 13-17

 

D-74653 Ingelfingen

 

Tel.  + 49 (0) 7940 - 10 91 111

 

Fax  + 49 (0) 7940 - 10 91 448

 

E-mail: [email protected]

international 

Contact addresses can be found on the final pages of the printed 

operating instructions.
And also on the Internet at: 

www.burkert.com

4.2 

Warranty

The warranty is only valid if the device is used as intended in accor-

dance with the specified application conditions.

4.3 

Information on the Internet

The operating instructions and data sheets for Type AC21 can be 

found on the Internet at: 

www.burkert.com

 

 Typ 6106

english

PTB 01 ATEX 2175

Summary of Contents for PTB 01 ATEX 2175

Page 1: ...ungsanleitung Manuel d utilisation PTB 01 ATEX 2175 Solenoid coil Type AC21 Magnetspule Typ AC21 Bobine magnetique AC21 Device with II 2G EX i approval Ger te mit II 2G EX i Zulassung Appareils avec m...

Page 2: ...right to make technical changes without notice Technische nderungen vorbehalten Sous r serve de modifications techniques 2002 2018 B rkert Werke GmbH Co KG Operating Instructions 1810 15_EU ML_008045...

Page 3: ...of the devices 8 5 1 Individual assembly block assembly 8 5 2 Operating temperature range 8 6 Technical data 8 6 1 Conformity 8 6 2 Standards 8 6 3 Operating conditions 8 7 Installation 12 7 1 Safety...

Page 4: ...t followed 1 1 Definition of terms In these instructions the term device always refers to the solenoid coil AC21 1 2 Symbols Danger Warns of an immediate danger Failure to observe the warning may resu...

Page 5: ...ation correct storage and installation as well as careful operation and maintenance Any other use is regarded as unauthorized B rkert is not liable for any result ing damage The user alone bears the r...

Page 6: ...ion The device is a closed system and must not be modified in any way A device which has already been used in a non hazardous i circuit must no longer be used in the hazardous i circuit as safety cann...

Page 7: ...power supply or pneumatic supply ensure that the process is restarted in a defined or controlled manner Don t use the device as a lever when screwing the valve into the line Failure to observe this o...

Page 8: ...solenoid coil type AC21 conforms to the EU Directives as per the EU Declaration of Conformity if applicable 6 2 Standards EN 60079 0 2018 EN 60079 11 2012 The applied standards which are used to demo...

Page 9: ...ee manual 6 Type serial number CE marking AC21 S N XXXXX CE0102 7 Order number date of manufacture xxxxxxxx month and year coded Tab 1 Description of the type label data 6 3 2 Coil dimensions Length m...

Page 10: ...T6 Gb 6 3 4 Use in temperature class T6 Ignition protection type Ex ia Gas group II C Temper ature class Max permitted ambient temperature C Assembly Max per mitted power consumption Pi W T6 40 60 Blo...

Page 11: ...The coils of type AC21 are available in two versions Version for use with 300 supply module 300 barrier High resistance version for use with other authorized supply modules Version Resis tance R20 Mi...

Page 12: ...e power supply and secure to prevent reactivation The connection lines of the electromagnets must be per manently installed in such a way that they are adequately protected from mechanical damage Obse...

Page 13: ...ed by electrostatic charge If there is a sudden discharge from electrostatically charged devices or persons there is a danger of explosion in the EX area Using suitable measures ensure that no electro...

Page 14: ...tected equipment may be damaged during transport During transportation protect the device against wet and dirt in shock resistant packaging Avoid exceeding or dropping below the allowable storage temp...

Page 15: ......

Page 16: ...www burkert com...

Reviews: