116
SAW sensor - Parameter
Type 8098
→
Do the settings for a special event (see
13.10.1, 13.10.3, and 13.10.5).
Is the event associated to the device
status
None
?
Yes
The event is disabled.
No
Is the event associated to the device
status
Normal state
10)
?
Yes
The event cannot be signalled by an
analogue output.
If the event is enabled, a message is
generated if the event occurs.
No
→
Select the behaviour of the analogue output(s)
for each device status (
Failure
,
Out of specifi
-
cation
and
Maintenance required
).
Is a digital output configured as an on/
off output?*) See chpt.
No
The event cannot be signalled by a
digital output.
Yes
If the event is enabled, it can be signalled by a digital output
configured as an on/off output.*)
The on/off output can be configured to switch:
•
depending on this single event.
• and/or, depending on
Failure
,
Out of specification
or
Main
-
tenance required
events.
→
Activate the
Diagnostics
in
General settings
-
Parameter
.
See chpt.
10.9 Activating the diagnostics functions.
Figure 24:
Flowchart: configuration of the diagnostics
10)
Normal state
means that only a message is generated when the event occurs but the event is considered to be
part of the normal operating of the process, or of the electronics, or of the sensor.
*
)
Only variant with outputs.
English