116
Storage
Type 8650 REV.2
22
sTORagE
note
Incorrect storage may damage the device.
▶
Store the device in a dry and dust-free location.
Storage temperature -40 – +70 °C
The following information applies to assemblies stored in the original packaging.
Requirement
permissible range
Free fall
≤1 m
Temperature
-40 – +70 °C
change in temperature max. 20 K/h
Air pressure
1,080– 660 hPa (equates to a height of -1,000 m – +3,500 m)
Relative humidity
5– 95 %, without condensation
AirLINE Ex exceeds the storage condition requirements of IEC 61131-2.