Operating modes of the MFC
Operating
mode
can be interrupted
or ended by
LED display
of default
Reaching the operating
status via binary input
(if configured)
Standard
control
operation
· Autotune routine
-
-
· Safety function
· Setpoint profile
· Control operation
Control
operation
· Autotune routine
LIMIT (y) LED
flashes
as long as activated
· Safety function
· Setpoint profile
Setpoint profile · Autotune routine
LIMIT (y) LED
flashes
Initiate with activated
binary input
≥
0.5 s
(if continuously
configured, repeated
starts)
· Safety function
· Device reset
Autotune
routine
· Safety function
· Device reset
POWER LED
flashes
Initiate with actifated
binary input
≥
0.5 s
(if continuously
configured, repeated
starts)
Safety function
-
LIMIT (y) LED
flashes
as long as activated