32 - MFC/MFM
english
Connection configuration Type 8710 / 8700
15-pole Sub-D plug
1
Relay output - NC contact
2
Relay output - NO contact
3
Relay output - C contact
4
GND 24 -V-supply and binary inputs
5
24 V
6
8 V output (For factory use only!)
7
Setpoint input GND
8
Setpoint input +
9
Process value output GND
10
Process value
11
DGND (for RS232)
12
Binary input 1
13
Binary input 2
14
RS232 RxD (without driver)
15
RS232 TxD (without driver)
DeviceNet - plug M12
1
Shield
2
VDD
3
DGND
4
CAN_H
5
CAN_L
1
VDD
2
RxD / TxD - N (A-line)
3
DGND
4
RxD / TxD - P (B-line)
5
Shield
Profibus DP-socket B-encoded M12
(DPV1 max. 12 Mbaud)
Only with fieldbus
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
2
3
4
1
5
5
2
1
4
3