6518 / 6519 - 17
I
NSTALLATION
, I
NITIALISATION
AND
S
ERVICE
english
Faults
Fault
Possible cause
Correction
Valve does not
switch
Operational voltage too low or
not present;
Check the electrical supply connections.
Ensure that the electrical power supply is the same as
that spe-cified on the rating plate.
Manual override not in neutral
position;
Set the manual override to the zero position.
Compressed air supply not
available or insufficient.
Carry out the dimensioning of the compressed air
connection with volumes as large as possi-ble (including
that of upstream pressure regulators, service units, cut-
off valves etc.)
Minimum operational pressure
2 bar
Valves switch
with a delay, or
exhaust
through the
venting ports:
Compressed air supply not
available or insufficient;
Führen Sie die Druckversorgung möglichst großvolumig
aus (auch bei vorgeschalteten Geräten wie
Druckreglern, Wartungseinheiten, Absperrventilen usw.).
Mindestbetriebsdruck
2 bar
Valves are not in the starting
position (whitout current)
during pressure build-up.)
Appley pressure to the valve block before you switch the
valves
Insufficient venting of the
exhaust channels due to
silencers that are too small or
are soiled (back-pressure);
Use silencers or expansion channels with sufficient
dimensions.
Clean soiled silencers.
Impurities or foreign matter in
the pilot valve or main valve.
Blast through the exhaust cahnnels with pulsed
compressed air, to blow out impurities. Install a new pilot
or main valve if these measures bring no improvement.
Leaking valve
block:
O-rings between the modu-
les missing or damaged;
Check for leaks and for missing seals.
Missing or incorrectly posi-
tioned profile gaskets be-
tween the valve and the
baseplate.
Install the missing seals and replace damaged seals.
Summary of Contents for 6518
Page 4: ...2 6518 6519 CONTENTS english ...
Page 8: ...6 6518 6519 GENERAL NOTES english ...
Page 20: ...18 6518 6519 INSTALLATION INITIALISATION AND SERVICE english Notes ...
Page 22: ...20 6518 6519 INHALT deutsch ...
Page 26: ...24 6518 6519 ALLGEMEINE HINWEISE deutsch ...
Page 38: ...36 6518 6519 MONTAGE INBETRIEBNAHME UND WARTUNG deutsch Notizen ...
Page 40: ...38 6518 6519 SOMMAIRE français ...
Page 44: ...42 6518 6519 REMARQUES GENERALES français ...
Page 57: ...The smart choice of Fluid Control Systems www buerkert com ...