14
Type 6516/6517 and type MP07
english
5/3 way valve:
in middle position, all outlet ports closed
5/3 way valve:
in middle position, Outlet Ports 2 and 4 vented,
Pressure Inlet 1 closed
3.4
Electrical connections
•
read the voltage, electrical power, type of protection and current from the rating plate!
•
voltage tolerance ±10%
•
electrical connection: Instrument socket type 2506 to the tag connection on the coil
(tightening torque: 1 Nm)
•
protection level IP 65 (only in combination with appliance socket type 2506)
•
to match the cable run, the instrument socket can be mounted rotated by 180°
•
refer to types 6106 or 8640 for other connection possibilities
ATTENTION!
NOTE
The pilot pressure of the pneumatic controller is dependent on the
pressure of the flow of medium:
it must not exceed a maximum of 8 bar!
3.3
Media
When screwing down the instrument socket onto the coil,
ensure that the flat seal is well seated!
ATTENTION!
•
filtered compressed air (max. particle size 10 µm), preferably non-oiled
•
operation is possible with oiled air
•
seal materials:
BP = Perbunam and polyurethane for 3/2 and 5/2 valves
BB = Perbunam and POM for 5/2 pulse and 5/3 valves
•
permissible medium temperature:
max. +50° C
•
permissible ambient temperature:
max. +55° C
•
operational pressure range:
2 - 8 bar
Observe the permissible pressure range given on the rating
plate!
Pressure difference between Ports 1 and 3/5
≥
≥
≥
≥
≥
2 bar