english
Operating Instructions-No. 803 118
13
3
GENERAL DESCRIPTION
3.1
Valve Construction
•
3/2 way pilot valve with various electrical connection possibilities
•
valve body with diaphragm, seat seal and weldet cover plates
•
2(B) / 4 (A) service ports plus supply and venting ports 1 (P) / 3 (S) / 5 (R), as option
with internal thread or plug-in connectors
•
the valves can be mounted on the modular pneumatic basic rail s type MP01 or MP02
to form valve blocks
•
Can be mounted in any position, preferably with the magnetic system at the top
•
Manual override for hand operation of the valve
NOTE
The valves require no maintenance, even for dry-air operation.
3.2
Valve operations of the Type 6510 / 6511 valves
3/2 way valve:
In de-energised position, Pressure Inlet 1 closed,
Outlet Port 2 exhausted
3/2 way valve:
In de-energised position, Pressure Inlet 1 connected
to Outlet Port 2
5/2 way valve:
In de-energised position, Pressure Inlet 1 connected
to Outlet Port 2, Outlet Port 4 exhausted.
ATTENTION!
For temperatures below 0° C, operation is limited to dry-air
operation!
3.3
Media
•
Filtered compressed air (max. particle size 5 µm), preferably non-oiled
•
Operation is possible with oiled air
•
Seal materials:
NBR and FPM
•
Permissible medium temperature:
max. +50° C
•
Permissible ambient temperature:
max. +55° C
•
Operational pressure range:
2,5 - 7 bar
Summary of Contents for 6510
Page 12: ...deutsch Betriebsanleitung Nr 803 118 9 5 NOTIZEN ...
Page 13: ...deutsch 10 Typ 6510 6511 u Typ MP01 MP02 ...
Page 22: ...english Operating Instructions No 803 118 19 5 NOTES ...
Page 23: ...english 20 Type 6510 6511 and type MP01 MP02 ...
Page 32: ...Instructions de service No 803 118 29 francais 5 NOTES ...
Page 33: ...30 Type 6510 6511 et type MP01 MP02 francais ...
Page 34: ...Instructions de service No 803 118 31 francais ...
Page 35: ...32 Type 6510 6511 et type MP01 MP02 francais ...